RD52.1-7N-160-R-M1-FW

MPN: R911200334

No Tariffs On US Orders
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The RD52.1-7N-160-R-M1-FW drive controller is air-cooled, features an integrated braking chopper, operates at a rated power of 160 kW, and supports a supply voltage of 3 x AC 380-480 V. Part of the RD 500 Drive Controllers by Bosch Rexroth Indramat, it includes IP20 protection and is designed for control cabinet mounting.

Quote Request Form:

Warranty
Wake Industrial Warranty
To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The RD52.1-7N-160-R-M1-FW RD 500 Drive Controller manufactured by Bosch Rexroth. This device is designed to control electric drives in industrial applications. It is built to deliver reliable performance in demanding environments. The RD 500 Drive Controllers offer a motor output of 160 kW which provides efficient power control.

The RD52.1-7N-160-R-M1-FW RD 500 Drive Controller operates with a supply voltage ranging from DC 530 to 670 V (~10%). The controller supports an output frequency from 0 to 250 Hz for flexible frequency regulation. The rated current for the drive controller is 230 A for stable and effective motor operation. It can handle a peak current of 299 A for up to 60 seconds and 391 A for 1 second. These capabilities allow the drive to manage dynamic load variations without compromising performance. With a rated output of 151 kVA, the controller confirms sufficient power capacity for demanding applications. The cooling is crucial for maintaining operational efficiency. The RD 500 Drive Controllers require a cooling air flow of 0.4 m^3/s. The cooling mode used is liquid cooling with an internal pump for optimal temperature management for long-lasting performance. The device features a power loss of 5.2 kW, which is typical for systems with such high output ratings.

The RD52.1-7N-160-R-M1-FW RD 500 Drive Controller uses line field-oriented regulation for precise control. It is designed as an inverter unit with a brake chopper, but without a built-in brake. The system also functions as a frequency converter which supports frequencies above 150 Hz. However it does not include an output choke. Overall, the drive controllers are engineered to deliver reliable and efficient performance in industrial drive control.

Cooling air requirement
0.4 m^3/s
Cooling mode
liquid cooling with internal pump
Motor output
160 kW
Output frequency
0 to 250 Hz
Peak current for t = 1 s
391 A
Peak current for t = 60 s
299 A
Power loss
5.2
Rated current
230 A
Rated output
151 kVA
Supply voltage
DC 530 to 670 V (~10 %)
Unit type
inverter
  • RD5217N160RM1FW
  • RD52 1 7N 160 R M1 FW
  • rd52.1-7n-160-r-m1-fw

Frequently Asked Questions about RD52.1-7N-160-R-M1-FW:

Q: What is the benefit of the RD52.1-7N-160-R-M1-FW RD 500's liquid cooling system?

A: The liquid cooling system ensures efficient temperature management, preventing overheating and extending the controller's operational life. This is critical for maintaining consistent performance under heavy loads.

Q: Why does the RD 500 Drive Controller have a peak current handling feature?

A: The peak current handling capability of 299 A for 60 seconds and 391 A for 1 second allows the drive to manage sudden dynamic load changes without performance degradation, providing a stable operation in fluctuating industrial environments.

Q: How does the frequency range from 0 to 250 Hz enhance the RD52.1-7N-160-R-M1-FW's flexibility?

A: The wide frequency range allows the controller to adapt to various motor types and operating conditions, offering precise control over motor speed and torque. This enables greater flexibility in industrial applications.

Q: What role does line field-oriented regulation play in the RD 500 Drive Controller?

A: The Line field-oriented regulation ensures precise and efficient motor control by optimizing the torque and flux within the motor, contributing to overall energy efficiency and enhanced system performance.

Q: Why does the RD 500 Drive Controller use an internal pump for cooling?

A: The internal pump facilitates the efficient circulation of cooling liquid within the unit, enhancing heat dissipation. This ensures stable performance by maintaining optimal operating temperatures, particularly in high-power applications.


Internal Product Review

  • ‘‘The RD52.1-7N-160-R-M1-FW RD 500 Drive Controller is highly efficient, featuring a 160 kW output and 230 A rated current. Its liquid cooling system and field-oriented regulation ensure long-term reliability. The product's peak current handling capabilities make it crucial for dynamic industrial operations.’’