RD52.1-4N-160-R-NN-FW/S109 Bosch Rexroth Indramat
Wake Industrial LLC is not an authorized distributor of this product.
MPN: R911200656
Ask for AvailabilityThe Bosch Rexroth Indramat RD52.1-4N-160-R-NN-FW/S109 is a drive controller from the RD 500 Drive Controllers series. It has a rated power of 160 kW and supports a voltage range of 380 to 480 V with a tolerance of ±10%. The controller features field oriented vector control, liquid cooling with an internal pump for units at or above 132 kW, and an integrated mains filter.
Internal Product Review
The RD52.1-4N-160-R-NN-FW/S109 is a Bosch Rexroth Indramat drive controller rated for 160 kW output. Field oriented vector control and an integrated mains filter give the unit very smooth regulation and clean system integration. Liquid cooling with an internal pump adds welcome thermal confidence, especially across the 380 to 480 V range.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
Bosch Rexroth Indramat builds the RD52.1-4N-160-R-NN-FW/S109 as part of the RD 500 Drive Controllers series. This liquid-cooled converter operates as a closed-loop AC drive controller, feeding variable-frequency power to high-power motors in automated presses, extruders, and material-handling systems. By regulating voltage, current, and frequency, it supplies precise speed and torque commands that integrate with PLC-based line controls. The unit acts as the interface between a plant's three-phase mains supply and the connected motor system, making it suitable for processes that require controlled acceleration, steady running speed, and repeatable load response.
The drive has a rated output of 160 kW, a capacity suited to high-power motor applications. The input network can vary between 380 to 480 V while remaining within a supply tolerance of ±10 %, allowing stable operation during common utility fluctuations. Motion control uses field-oriented vector control, so torque remains closely proportional to current even at low shaft speeds. This control method is useful where smooth response is needed during startup, speed changes, or varying load conditions. Thermal stability is provided by liquid cooling with an internal pump, which removes heat from the power section and supports continuous operation under demanding duty cycles. Optional technology functions are not installed.
In operation, power enters through a three-phase AC converter front end, and electromagnetic interference is attenuated by the factory-installed integrated mains filter. The hardware is categorized as Generation 1, so its dimensions and connector layout follow the first RD500 cabinet release. The unit is supplied without a built-in brake chopper, so dynamic braking energy must be handled externally. This layout separates the braking function from the converter itself and leaves room for system-level braking components where required. No application-specific function boards are fitted.