4.95 based on 202 reviews

🙶 Wake was very helpful in getting us a servo motor and drive for our tube mill line. This was the first tim... 🙷

RD52.1-4N-160-R-NN-FW Bosch Rexroth Indramat

MPN: R911200446

No Tariffs On US Orders
  • Rated 4.5 (57 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat RD52.1-4N-160-R-NN-FW is a drive controller from the RD 500 Drive Controllers series. It features a rated power of 160 kW and operates on 3-phase AC within a voltage range of 380 to 480 V, with a tolerance of ±10%. The drive uses field oriented vector control and utilizes liquid cooling with an internal pump for models rated 132 kW or higher.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The RD52.1-4N-160-R-NN-FW is a drive controller produced by Bosch Rexroth Indramat within the RD 500 Drive Controllers series. As a converter, it regulates three-phase motor power in automated machinery, allowing precise speed and torque commands from higher-level control systems. The unit forms the interface between the plant’s line supply and the motor shafts, making it central to coordinated motion on production lines, test benches, and continuous process equipment. In this role, it adjusts output frequency and voltage as process demand rises or falls, which supports smooth starts, controlled acceleration, and stable running at target speed.

This controller operates on a line voltage of 380 to 480 V, a range that covers common industrial distribution levels and permits global installation without internal tap changes. It draws energy through a three-phase AC converter input, then synthesizes a variable-frequency output matched to the connected motor set. The power stage is rated for 160 kW, so it can drive large pumps, extruders, or multi-motor groups while maintaining thermal limits. High losses are removed by liquid cooling with an internal pump, a method that keeps semiconductor temperatures stable when installed power is high and cabinet airflow alone is insufficient. Motor flux and torque are handled through field-oriented vector control, enabling dynamic response and low-speed accuracy that scalar methods cannot deliver.

The power section is supplied without a built-in brake chopper, so external energy-dissipation hardware is needed only when regenerative peaks are expected. An integrated line filter attenuates conducted emissions and helps reduce the need for extra input components. The allowable input variation is ±10% input tolerance, which helps the controller remain functional during utility fluctuations or transformer tap errors. Control software is not preloaded, and firmware must be ordered separately so the installed functions match the target machine. This allows the drive to be prepared for the intended operating mode rather than including unused software functions.

Brake Chopper
Without built-in brake chopper
Control Type
Field oriented vector control
Cooling Type
Liquid cooling with internal pump (>= 132 kW)
Design Generation
1
Firmware Note
Firmware must be ordered as separate subposition
Functions
Not equipped
Mains Filter
Integrated
Product Type
Drive Controller
Rated Power
160 kW
Supply Type
Converter 3 x AC
Tolerance
±10 %
Voltage Range
380 to 480 V
  • RD5214N160RNNFW
  • RD52 1 4N 160 R NN FW
  • rd52.1-4n-160-r-nn-fw

Frequently Asked Questions about RD52.1-4N-160-R-NN-FW:

Q: What is the rated power of the RD52.1-4N-160-R-NN-FW drive controller?

A: This model operates with a rated power output of 160 kW.

Q: What cooling method is used for the RD52.1-4N-160-R-NN-FW?

A: The RD52.1-4N-160-R-NN-FW is liquid cooled using an internal pump for high-power dissipation.

Q: What supply voltage is required for the RD52.1-4N-160-R-NN-FW controller?

A: It is designed to operate on a 3-phase AC supply with a voltage range from 380 to 480 V.

Q: What control type does the RD52.1-4N-160-R-NN-FW utilize?

A: This drive controller uses field oriented vector control for precise motor management.

Q: Is a mains filter included with the RD52.1-4N-160-R-NN-FW?

A: The RD52.1-4N-160-R-NN-FW includes an integrated mains filter to limit electrical noise.


Internal Product Review

  • ‘‘The RD52.1-4N-160-R-NN-FW is a Bosch Rexroth Indramat drive controller built for converter 3 x AC supply and field oriented vector control. Liquid cooling with internal pump supports stable thermal management, and the integrated mains filter simplifies panel integration. Rated at 160 kW across a 380 to 480 V range, the unit stands out as a strong choice for high-demand drive applications.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo