RD52.1-4N-110-L-V1-FW Bosch Rexroth Indramat
MPN: R911200568
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat RD52.1-4N-110-L-V1-FW is a drive controller from the RD 500 Drive Controllers series. It provides a rated power of 110 kW and operates within a voltage range of 380 to 480 V AC with a 10 percent tolerance. This unit uses forced air cooling, field oriented vector control, and comes with an integrated mains filter and external 24 V stand-by power function.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The industrial motion product RD52.1-4N-110-L-V1-FW is a drive controller manufactured by Bosch Rexroth Indramat and assigned to the RD 500 Drive Controllers series. Within an automation cell, this unit interfaces with a three-phase mains supply and a motor inverter stage, delivering closed-loop regulation of speed and torque for large AC machines. By coordinating current, voltage, and frequency, it enables precise process control for conveyors, extruders, and similar high-demand loads in continuous-duty production.
This controller is specified for a nominal output of 110 kW, giving it the capacity to operate sizable induction or synchronous motors without derating at rated line conditions. Vector modulation is accomplished through field-oriented vector control, which adjusts stator currents to align with rotor flux and maintain dynamic torque response. The power section accepts line voltages from 380 to 480 V, and the front end is engineered as a three-phase AC converter so installation is tied directly to a three-phase mains transformer or busbar. Heat generated by the IGBT stack is removed through forced air cooling, allowing cabinet temperatures to stay within component limits during continuous full-load operation. Generation 1 design conventions govern the mechanical layout, and the unit accommodates the stated input tolerance during normal operation.
The power stage is supplied without a built-in brake chopper, so dynamic braking requires an external resistor module when rapid deceleration is needed. Line-side interference is minimized by an integrated mains filter, which reduces conducted emissions into the facility network. Control electronics remain energized during main power isolation through 24 V standby power, furnished from an external supply for parameter retention and fieldbus communication. Component ratings tolerate supply deviations of ±10 %, permitting operation on utility feeds with moderate voltage variation.
Frequently Asked Questions about RD52.1-4N-110-L-V1-FW:
Q: What is the rated power output for the RD52.1-4N-110-L-V1-FW drive controller?
A: The RD52.1-4N-110-L-V1-FW controller has a rated power output of 110 kW.
Q: What type of power supply connection does the RD52.1-4N-110-L-V1-FW require?
A: Its supply type is Converter 3 x AC, suitable for industrial three-phase power systems.
Q: How is the RD52.1-4N-110-L-V1-FW drive controller cooled during operation?
A: This model features forced air cooling to maintain operational temperatures.
Q: Does the RD52.1-4N-110-L-V1-FW come with a built-in mains filter?
A: The device includes an integrated mains filter for line disturbance protection.
Q: What type of motor control method does the RD52.1-4N-110-L-V1-FW use?
A: The control type is field oriented vector control for precise motor management.