RD52.1-4N-045-L-V1-FW Bosch Rexroth Indramat
MPN: R911200381
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat RD52.1-4N-045-L-V1-FW is a drive controller from the RD 500 Drive Controllers series with a rated power of 45 kW and operates on a voltage range of 380 to 480 volts. It features field oriented vector control, forced air cooling, and has an integrated mains filter. This model includes 24 V external stand-by power and does not have a built-in brake chopper.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The Bosch Rexroth Indramat RD52.1-4N-045-L-V1-FW drive controller belongs to the RD 500 Drive Controllers series. It functions as a three-phase AC converter that regulates induction or synchronous motor output inside automated assembly stations and continuous-process lines. By implementing vector-based current modulation, the unit links plant-level control systems to shop-floor actuators, ensuring commanded torque values are delivered accurately while maintaining energy efficiency in variable-speed applications.
Its motion algorithms rely on field-oriented vector control, so torque and flux components are calculated separately for fast dynamic response. Cooling is managed through forced air cooling, and a cabinet fan directs airflow along the heat sink to keep semiconductor junction temperatures within limits during high current cycles. Because the controller is supplied without a built-in brake chopper, excess regenerative energy must be routed to an external resistor when decelerating large inertial loads. An integrated mains filter attenuates conducted emissions, allowing installation on industrial low-voltage networks without additional line filters. The power section accepts line voltages from 380 to 480 V, matching typical 400 V utility grids in manufacturing plants.
Within this range, it can deliver a continuous output of 45 kW, providing adequate headroom for medium-frame pumps, fans, or conveyor drives. The front-end rectifier is designed for a three-phase AC converter supply, so current is drawn symmetrically from all phases and conforms to a tolerance of ±10 % on the nominal input. Control electronics remain active through the provision for 24 V standby power, allowing fieldbus communication and parameter retention when the main power stage is de-energized. The unit uses generation 1 hardware and keeps the same mechanical mounting footprint.
Frequently Asked Questions about RD52.1-4N-045-L-V1-FW:
Q: What is the rated power output of the RD52.1-4N-045-L-V1-FW drive controller?
A: The RD52.1-4N-045-L-V1-FW features a rated power output of 45 kW.
Q: What type of supply does the RD52.1-4N-045-L-V1-FW use?
A: This model operates on a three-phase AC converter supply.
Q: What cooling method is used in the RD52.1-4N-045-L-V1-FW?
A: Forced air cooling is used to manage heat in this drive controller.
Q: Does the RD52.1-4N-045-L-V1-FW come with an integrated mains filter?
A: The RD52.1-4N-045-L-V1-FW includes an integrated mains filter.
Q: What control type does the RD52.1-4N-045-L-V1-FW use?
A: Field oriented vector control is utilized for precise drive control in this unit.