RD52.1-4B-037-L-V1-FW Bosch Rexroth Indramat
MPN: R911200222
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat RD52.1-4B-037-L-V1-FW drive controller is part of the RD 500 Drive Controllers series and features a built-in brake chopper and integrated mains filter. It supports field oriented vector control, uses forced air cooling, and is rated for 37 kW power with an operating voltage range of 380 to 480 Volts.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The RD52.1-4B-037-L-V1-FW is a drive controller manufactured by Bosch Rexroth Indramat for the RD 500 Drive Controllers series. It converts fixed-frequency mains power into a variable-voltage, variable-frequency output that matches motor torque and speed demands in industrial automation cells. By executing vector algorithms on its internal processor, the device delivers precise current control for conveyors, pumps, and spindle axes. This operating method helps the motor respond smoothly to changing loads while maintaining stable speed across a broad working range. It is well suited for applications that need controlled acceleration, steady process speed, and repeatable torque delivery during duty-cycle changes.
The unit is a three-phase AC converter that accepts line voltages from 380 to 480 V. Its power section is rated for 37 kW, allowing it to operate medium-sized induction motors without additional power-conversion equipment. Speed and torque are regulated through field-oriented vector control, which continuously evaluates phase current and adjusts switching commands for accurate motor behavior. During deceleration, the integrated built-in brake chopper diverts regenerated energy to an external resistor instead of returning it to the mains. A factory-installed mains filter reduces conducted interference before it reaches upstream electrical distribution and helps limit switching noise on shared plant power lines.
Heat is removed by forced air cooling, so the enclosure needs a clear path for intake and exhaust airflow. The control electronics can remain active during machine shutdowns because a 24 V standby power input supplies the logic board even when the main power section is off. This separate supply allows the control section to remain available for monitoring and command handling while the power stage is inactive. The drive tolerates line variation of ±10 % without losing regulation, which helps it remain stable where plant voltage fluctuates under normal loading. It is identified as Design Generation 1 in the product line.
Frequently Asked Questions about RD52.1-4B-037-L-V1-FW:
Q: What is the rated power output of the RD52.1-4B-037-L-V1-FW controller?
A: The RD52.1-4B-037-L-V1-FW drive controller offers a rated power of 37 kW.
Q: What input voltage range does the RD52.1-4B-037-L-V1-FW support?
A: This model operates on a voltage range from 380 to 480 V.
Q: What cooling method is used in the RD52.1-4B-037-L-V1-FW drive controller?
A: The RD52.1-4B-037-L-V1-FW uses forced air cooling.
Q: Does the RD52.1-4B-037-L-V1-FW feature an integrated brake chopper?
A: A built-in brake chopper is included in this drive controller.
Q: Is a mains filter included in the RD52.1-4B-037-L-V1-FW controller?
A: This drive controller is equipped with an integrated mains filter for improved operation.