RD52.1-4B-001-L-NN-L2-T1-FW Bosch Rexroth Indramat
MPN: R911288653
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat RD52.1-4B-001-L-NN-L2-T1-FW is a drive controller from the RD 500 Drive Controllers series. It features a built-in brake chopper, forced air cooling, and operates on a voltage range of 380 to 480 V. The controller uses field oriented vector control and includes an integrated mains filter.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The RD52.1-4B-001-L-NN-L2-T1-FW is a drive controller produced by Bosch Rexroth Indramat within the RD 500 Drive Controllers series. As a closed-loop power electronics module, it interfaces between a three-phase supply and an AC motor to manage speed, torque, and dynamic braking in automated machinery. In production lines, packaging cells, or material-handling stations, the unit supplies regulated voltage and current so the connected motor can follow motion profiles from a higher-level PLC. This arrangement allows the drive to correct load-related speed error and maintain predictable motor response during acceleration, steady running, and braking.
The power section is designed for a 380 to 480 V network and operates as a Converter 3 x AC, so the rectifier and intermediate DC link are integrated for direct line connection. Input fluctuations of ±10 % are permitted without shutdown, which helps the drive remain stable on industrial power systems with modest voltage variation. Current and flux are processed with field-oriented vector control, which separates stator current into torque-producing and magnetizing components for more linear motor response. A built-in brake chopper handles excess DC link energy during rapid deceleration by routing it to an external resistor. Because the conversion stage is integrated, no separate external rectifier is required for normal operation on the stated supply range.
Installation is simplified by the integrated mains filter, which suppresses conducted emissions and often removes the need for a separate RFI line filter in the control cabinet. Thermal management is handled by forced air cooling, so the enclosure must provide a clear intake and exhaust path for the fan assembly. The unit is design generation 1, which matches first-generation RD 500 option cards for I/O or communication expansion. The optional function slot is not equipped, so no encoder interface or fieldbus module is installed in the base configuration. Leaving the slot open keeps the base unit focused on core drive functions while still allowing interface expansion if needed.