RD51.1-8N-007-L-V1-FW Bosch Rexroth Indramat
MPN: R911200709
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat RD51.1-8N-007-L-V1-FW is a drive controller in the RD 500 Drive Controllers series. It has a rated power of 7.5 kW and operates on inverter DC supply with a voltage range of 700 V. The product features U/f curve control, forced air cooling, and external 24 V stand-by power, and does not include a built-in brake chopper.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The RD51.1-8N-007-L-V1-FW drive controller is built by Bosch Rexroth Indramat within the RD 500 Drive Controllers series. It is a three-phase inverter that supplies adjustable voltage and frequency to standard induction motors, allowing process machinery to vary speed while maintaining torque consistency. In automated production cells, the unit links a shared DC bus to individual motor zones, so one controller can decelerate a load and another can draw that recovered energy, improving overall line efficiency.
This model operates without a built-in brake chopper; therefore, any regenerative energy must be routed through an external resistor or common DC link module. Its modulation strategy is based on U/f curve control, a method that keeps the motor's magnetic flux constant across the speed range and is suited for conveyor, pump, and fan applications that do not need vector feedback. Thermal management relies on forced air cooling, and a rear-mounted blower moves cabinet air across the heat sink to hold semiconductor temperatures within safe limits. The inverter is rated for 7.5 kW of continuous mechanical output when fed from a 700 V DC bus, so drive sizing must account for both steady-state and acceleration power demands.
It belongs to design generation 1, which determines compatible option cards and wiring layouts used in the drive cabinet. Control electronics remain energized through an external 24 V standby power input, allowing fieldbus communication and parameter access while the main DC link is off. Mains rectification is not included; instead, the unit expects an inverter DC supply from a front-end converter rather than a direct AC input. Application-specific functions are provided through separately ordered firmware, so software features can be matched to the target motion profile without changing hardware.
Frequently Asked Questions about RD51.1-8N-007-L-V1-FW:
Q: What is the rated power output of the RD51.1-8N-007-L-V1-FW drive controller?
A: The RD51.1-8N-007-L-V1-FW drive controller delivers a rated power output of 7.5 kW.
Q: What type of control does the RD51.1-8N-007-L-V1-FW use?
A: This drive controller utilizes U/f curve control for motor operation.
Q: What supply voltage and type are required for the RD51.1-8N-007-L-V1-FW?
A: The RD51.1-8N-007-L-V1-FW operates with a supply voltage of 700 V using an inverter DC supply.
Q: How is cooling achieved in the RD51.1-8N-007-L-V1-FW drive controller?
A: Forced air cooling is used in this model to manage heat during operation.
Q: Does the RD51.1-8N-007-L-V1-FW come with a built-in brake chopper?
A: This unit does not include a built-in brake chopper.