RD51.1-7N-045-L-V1-FW/S122 Bosch Rexroth Indramat
Wake Industrial LLC is not an authorized distributor of this product.
MPN: R911201080
Ask for AvailabilityThe Bosch Rexroth Indramat RD51.1-7N-045-L-V1-FW/S122 is a drive controller from the RD 500 Drive Controllers series. It supports a rated power of 45 kW and uses U/f curve control with forced air cooling. This inverter DC model operates on a voltage range of 530 to 670 V and features external 24 V stand-by power.
Internal Product Review
The RD51.1-7N-045-L-V1-FW/S122 is a Bosch Rexroth Indramat drive controller designed for inverter DC applications with a 45 kW rated power. Forced air cooling supports stable thermal performance, and U/f curve control gives the unit dependable behavior in variable-speed drive systems. A strong choice for industrial drive integration, especially across the 530 to 670 V range.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The RD51.1-7N-045-L-V1-FW/S122 drive controller is produced by Bosch Rexroth Indramat and belongs to the RD 500 Drive Controllers series. Serving as a variable-speed inverter, it transforms a fixed DC link into a programmable three-phase output so that induction motors in automated lines can match process speed requirements. By positioning itself between higher-level PLC commands and the motor terminals, the unit supplies precise voltage-frequency patterns that support conveyor, pump, and mixer duties in industrial automation.
The unit is supplied without a built-in brake chopper, so dynamic braking must be handled by an external resistor assembly when rapid deceleration is required. Regulation is achieved through U/f curve control, a method that keeps the voltage-to-frequency ratio constant to prevent magnetic saturation in standard squirrel-cage machines. Thermal management depends on forced air cooling; internal fans move ambient air across heat sinks to maintain semiconductor junction temperatures. It is part of design generation 1, meaning its frame size and connector layout align with the initial RD51 mechanical standard. Under nominal conditions, the inverter can drive loads up to 45 kW, establishing the baseline for cable sizing, fuse selection, and overload settings in the control cabinet.
An external 24 V standby power input keeps the control circuitry energized during mains isolation, allowing fieldbus communication and parameter monitoring without engaging the high-power stage. Because application software is user-selectable, firmware must be ordered as a separate subposition. The internal bus is charged from an inverter DC source, and all link components are rated for operation within 530 to 670 V, a window that accommodates regenerative voltage rises while protecting the IGBTs.