RD51.1-7N-045-L-V1-FW Bosch Rexroth Indramat
MPN: R911200710
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat RD51.1-7N-045-L-V1-FW is a drive controller from the RD 500 Drive Controllers series with a rated power of 45 kW and operates within a voltage range of 530 to 670 V. It uses U/f curve control and features forced air cooling, without a built-in brake chopper.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The RD51.1-7N-045-L-V1-FW drive controller is produced by Bosch Rexroth Indramat and belongs to the RD 500 Drive Controllers series. As an inverter for industrial automation, it modulates DC bus energy into variable-frequency, variable-voltage three-phase power, allowing standard induction motors to run at commanded speeds and torques on production lines and process equipment. The unit provides basic open-loop vector performance for applications where encoder feedback is unnecessary, which reduces wiring complexity. Its modular construction separates the power section from the control card, so motor leads do not need to be rewired during service.
Its rated output is 45 kW, giving it the capacity to run pumps, conveyors, and fans in industrial systems. The power section accepts a DC link between 530 to 670 V, so it can connect directly to a rectifier module in DC bus systems. Speed regulation uses U/f curve control, which keeps stator voltage proportional to frequency to maintain magnetic flux across the speed range. This method supports steady motor operation in applications where closed-loop feedback is not required. Heat is removed by forced air cooling; internal fans pull cabinet air through finned heat sinks to keep the IGBTs within safe temperature limits. The unit is supplied without a built-in brake chopper, so regenerated energy must be handled by an external resistor grid or returned to the shared bus.
During idle periods, a low-voltage input supplies 24 V standby power, allowing the control board to remain energized for fieldbus communication and parameter retention. The unit is Design Generation 1 and uses first-generation RD500 keypad panels and option slots. Its DC interface follows the Inverter DC arrangement, so the controller draws energy from the DC link instead of an internal rectifier. That arrangement suits installations built around a shared DC supply architecture. Application logic is not factory-loaded, and the required software is ordered separately.