RD51.1-7N-022-L-V1-FW Bosch Rexroth Indramat
MPN: R911200966
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat RD51.1-7N-022-L-V1-FW is a drive controller from the RD 500 Drive Controllers series. It uses U/f curve control with a rated power of 22 kW and operates within a voltage range of 530 to 670 V DC. This first generation model features forced air cooling and is designed without a built-in brake chopper.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The RD51.1-7N-022-L-V1-FW drive controller is produced by Bosch Rexroth Indramat within the RD 500 Drive Controllers series. In plant automation, it regulates induction motor speed and torque by processing DC-bus energy and producing a variable AC output. By working with programmable logic controllers and upstream power sections, the unit supports closed-loop motion control for conveyors, pumps, and fans while maintaining stable motor operation across a broad operating range. This type of control helps the driven machine follow changing process demand without the abrupt starts associated with direct-on-line motor connection.
This model operates from a DC link between 530 to 670 V, a span that accommodates common 600 V industrial rectifier installations. Because the supply uses an Inverter DC link rather than direct mains input, the controller fits systems that distribute power through a centralized conversion stage. The controller relies on forced air cooling, and internal fans move air across heat sink surfaces to remove switching losses without external chillers. Its nominal output of 22 kW gives the unit its maximum continuous mechanical power for the connected motor system. Speed is controlled through U/f curve control, which keeps the relationship between stator voltage and frequency consistent during acceleration and load changes.
The unit operates without a built-in brake chopper, so rapid deceleration requires an external braking solution when regenerated energy must be dissipated. The control circuit accepts external 24 V standby power, which allows logic functions to remain active when the main DC bus is switched off. The hardware is categorized as Design generation 1, which matches the first generation of RD 500 accessories and related option modules. The required firmware must be ordered as a separate subposition, allowing the software package to be selected for the intended application and communication setup. This arrangement separates the hardware platform from the control software so the unit can be prepared for different operating tasks without changing the main drive controller body.
Frequently Asked Questions about RD51.1-7N-022-L-V1-FW:
Q: What is the rated power of the RD51.1-7N-022-L-V1-FW drive controller?
A: The RD51.1-7N-022-L-V1-FW operates with a rated power output of 22 kW.
Q: What control method does the RD51.1-7N-022-L-V1-FW utilize?
A: This unit uses U/f curve control for motor regulation.
Q: What cooling method is implemented on the RD51.1-7N-022-L-V1-FW?
A: Forced air cooling is used to manage the temperature of this drive controller.
Q: Does the RD51.1-7N-022-L-V1-FW have an integrated brake chopper?
A: The RD51.1-7N-022-L-V1-FW does not include a built-in brake chopper.
Q: How is 24 V stand-by power supplied on the RD51.1-7N-022-L-V1-FW?
A: Users must provide 24 V stand-by power from an external source for this device.