The Bosch Rexroth Indramat RD51.1-7N-015-L-NN-FW is a drive controller in the RD 500 Drive Controllers series with a rated power of 15.0 kilowatts. It features U/f curve control, operates on a DC inverter supply voltage of 530 to 670 volts, and uses forced air cooling. This model is designed without a built-in brake chopper and is from the first design generation.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The RD51.1-7N-015-L-NN-FW is a drive controller produced by Bosch Rexroth Indramat for the RD 500 Drive Controllers series. It converts DC-bus supply power into adjustable voltage and frequency for induction motors used in conveyors, mixers, pumps, and other industrial motion equipment. Because it works as an inverter stage instead of a complete mains-input drive, it fits modular systems that separate rectification from motor control. That arrangement allows several drive sections to operate from a shared bus while each motor still receives speed control suited to its process.
The RD51.1 uses U/f curve control, so output frequency follows a preset voltage-to-frequency relationship that helps standard induction motors maintain usable torque across a broad speed range. It accepts a DC bus window of 530 to 670 V, which matches common rectifier sections on 400 VAC class mains. Within that range, it can deliver up to 15.0 kW of motor power, making it suitable for medium-duty fan, pump, and conveyor service. The power stage is designed for an Inverter DC link rather than direct AC mains input. Thermal management uses forced air cooling, and an internal fan moves air through the heat sink to control semiconductor temperature during continuous operation.
This controller is part of Generation 1 of the product line, so it follows the first-generation platform used in the RD family. It is supplied without a built-in brake chopper, which means braking energy from overhauling or fast-decelerating loads must be handled by external hardware when required. The control board uses firmware ordered as a separate subposition rather than preloaded software. Its option slots are not equipped, leaving room for later addition of application-specific I/O or communication cards. That layout is useful when a base inverter is selected first and interface functions are added only when the application requires them.
Frequently Asked Questions about RD51.1-7N-015-L-NN-FW:
Q: What is the rated power output of the RD51.1-7N-015-L-NN-FW drive controller?
A: The RD51.1-7N-015-L-NN-FW drive controller offers a rated power output of 15.0 kW for industrial applications.
Q: What control method does the RD51.1-7N-015-L-NN-FW drive controller use?
A: This model uses U/f curve control for managing motor speed and torque.
Q: What is the input voltage range for the RD51.1-7N-015-L-NN-FW drive controller?
A: The RD51.1-7N-015-L-NN-FW operates within a voltage range of 530 to 670 V for its input supply.
Q: How is the RD51.1-7N-015-L-NN-FW drive controller cooled?
A: Forced air cooling is utilized in this drive controller to manage its thermal conditions.
Q: Is a brake chopper included in the RD51.1-7N-015-L-NN-FW drive controller?
A: This model does not include a built-in brake chopper.