4.95 based on 202 reviews

🙶 Wake was very helpful in getting us a servo motor and drive for our tube mill line. This was the first tim... 🙷

RD51.1-5N-110-L-DL-FW Bosch Rexroth Indramat

MPN: R911200929

No Tariffs On US Orders
  • Rated 4.6 (45 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat RD51.1-5N-110-L-DL-FW is a drive controller from the RD 500 Drive Controllers series with a rated power of 110 kW and a voltage range of 500 V. It uses U/f curve control with forced air cooling and is designed as a converter for 3-phase AC supply. This unit features a NAMUR terminal strip with external 24 V stand-by power and supports feedback of cable damping.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The RD51.1-5N-110-L-DL-FW is a drive controller manufactured by Bosch Rexroth Indramat and belongs to the RD 500 Drive Controllers series. The device converts fixed mains power into variable output for asynchronous motors, enabling speed and torque regulation in automated conveyors, fans, and processing equipment. Mounted inside a control cabinet, it functions as the central power stage that links PLC commands to motor terminals during continuous industrial duty. This arrangement allows the motor to respond smoothly to changing process demands without requiring direct manual adjustment at the load.

Rated output is 110 kW, indicating the maximum mechanical power the inverter can deliver under nominal conditions. The supply section is a converter 3 × AC, so it rectifies three-phase line voltage before synthesizing a variable AC waveform. That input must lie within the 500 V range used by this model for safe operation. Speed modulation is performed with U/f curve control, which keeps voltage and frequency proportional so magnetic flux remains stable as load conditions change. Thermal energy generated by the power semiconductors is removed through forced air cooling, with an integrated fan directing airflow along the heat sink to keep internal temperatures within operating limits. This cooling method supports steady operation during prolonged runtime in enclosed industrial cabinets.

The unit is delivered without a built-in brake chopper, so external chopper circuitry or a braking resistor must be added when regenerative energy is expected. Hardware classification follows design generation 1, so connector placement and parameter numbering match other first-generation RD controllers. Field wiring is grouped on a NAMUR terminal strip, which helps organize control connections in a consistent layout. For long motor leads, the drive provides feedback of cable damping, allowing the control board to compensate for reactive losses and sustain commanded torque accuracy across extended cable lengths. The linked 24 V stand-by input keeps status circuits energized when the main bus is isolated, which helps preserve control visibility during service conditions.

Brake Chopper
Without built-in brake chopper
Control Type
U/f curve control
Cooling Type
Forced air cooling
Design Generation
1
Firmware Note
Firmware must be ordered as separate subposition
Function 1
NAMUR terminal strip, 24 V stand-by power external
Function 2
Feedback of cable damping (C3, D3)
Product Type
Drive Controller
Rated Power
110 kW
Supply Type
Converter 3 x AC
Voltage Range
500 V
  • RD5115N110LDLFW
  • RD51 1 5N 110 L DL FW
  • rd51.1-5n-110-l-dl-fw

Frequently Asked Questions about RD51.1-5N-110-L-DL-FW:

Q: What is the rated power of the RD51.1-5N-110-L-DL-FW drive controller?

A: The RD51.1-5N-110-L-DL-FW supports a rated power output of 110 kW for high-capacity applications.

Q: What supply type and voltage range does the RD51.1-5N-110-L-DL-FW require?

A: This drive controller operates using a supply input of 3-phase AC with a voltage range of 500 V.

Q: How is the RD51.1-5N-110-L-DL-FW drive controller cooled during operation?

A: The RD51.1-5N-110-L-DL-FW utilizes forced air cooling to maintain optimal operating temperatures.

Q: What control method is supported by the RD51.1-5N-110-L-DL-FW?

A: It features U/f curve control, providing standard variable frequency drive operation.

Q: Does the RD51.1-5N-110-L-DL-FW drive controller have a built-in brake chopper?

A: This model does not include a built-in brake chopper.


Internal Product Review

  • ‘‘The RD51.1-5N-110-L-DL-FW is a Bosch Rexroth Indramat drive controller with U/f curve control and forced air cooling. The converter 3 x AC supply and 500 V voltage range support dependable integration in demanding drive systems. A 110 kW rated power and NAMUR terminal strip configuration make this unit a strong option for industrial applications.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo