4.95 based on 202 reviews

🙶 Easy to navigate website and quick responses from support. Additionally, pretty fast shipping. Our mainte... 🙷

RD51.1-5N-045-L-DL-FW Bosch Rexroth Indramat

MPN: R911200664

No Tariffs On US Orders
  • Rated 4.4 (52 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat RD51.1-5N-045-L-DL-FW is a drive controller from the RD 500 Drive Controllers series. It has a rated power of 45 kW with a voltage range of 500 V and uses U/f curve control. The unit features forced air cooling and operates as a converter for three-phase AC supply.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The RD51.1-5N-045-L-DL-FW is a drive controller manufactured by Bosch Rexroth Indramat for the RD 500 Drive Controllers series. It interfaces with three-phase induction motors and provides variable-speed operation for conveyors, pumps, and additional motion axes in automated plants. By converting fixed-frequency utility power into a commanded output, the device supports controlled acceleration and stable torque delivery during continuous industrial operation. That makes it useful on process machinery that starts, stops, and changes speed throughout the shift.

This model supplies up to 45 kW of mechanical power while maintaining stable motor excitation. It is intended for 500 V mains and uses a three-phase AC converter topology, so incoming line voltage is rectified and then modulated by the inverter stage. Drive regulation uses U/f curve control, which raises voltage in proportion to frequency to support steady magnetic flux in open-loop motor applications. This control method is commonly used on fans, pumps, and conveyors where simple frequency-based speed regulation is appropriate. Heat is removed by forced-air cooling, and the airflow path must remain clear to avoid thermal derating during extended high-load operation.

The unit operates without a built-in brake chopper, so dynamic braking requires external hardware when the driven load returns energy to the DC bus. Its control interface uses a NAMUR terminal strip with external 24 V standby power, which allows status and control functions to remain available when main power is removed. For long motor cable runs, cable-damping feedback (C3, D3) helps offset signal losses that can affect commanded torque at the motor terminals. The entry firmware ordered as a separate subposition indicates that the required software package is selected separately from the base hardware. Separate braking and software selection can help match the controller to plant requirements and motor-cable layouts.

Brake Chopper
Without built-in brake chopper
Control Type
U/f curve control
Cooling Type
Forced air cooling
Design Generation
1
Firmware Note
Firmware must be ordered as separate subposition
Function 1
NAMUR terminal strip, 24 V stand-by power external
Function 2
Feedback of cable damping (C3, D3)
Product Type
Drive Controller
Rated Power
45 kW
Supply Type
Converter 3 x AC
Voltage Range
500 V
  • RD5115N045LDLFW
  • RD51 1 5N 045 L DL FW
  • rd51.1-5n-045-l-dl-fw

Frequently Asked Questions about RD51.1-5N-045-L-DL-FW:

Q: What is the voltage range for the RD51.1-5N-045-L-DL-FW drive controller?

A: The RD51.1-5N-045-L-DL-FW drive controller operates on a voltage range of 500 V, supporting high-voltage industrial applications.

Q: What is the rated power capability of the RD51.1-5N-045-L-DL-FW?

A: This drive controller has a rated power output of 45 kW for demanding motor control tasks.

Q: What cooling method does the RD51.1-5N-045-L-DL-FW utilize?

A: The RD51.1-5N-045-L-DL-FW uses forced air cooling to maintain optimal operating temperatures during use.

Q: Which control type is implemented in the RD51.1-5N-045-L-DL-FW drive controller?

A: U/f curve control is used on this model, offering simple and robust motor control for various drive applications.

Q: What special terminal and stand-by power features are available on the RD51.1-5N-045-L-DL-FW?

A: The RD51.1-5N-045-L-DL-FW is equipped with a NAMUR terminal strip and supports 24 V stand-by power supplied externally.


Internal Product Review

  • ‘‘The RD51.1-5N-045-L-DL-FW is a Bosch Rexroth Indramat drive controller that stands out for smooth U/f curve control and effective forced air cooling. Rated for 45 kW and 500 V, the design fits demanding drive applications with consistent output characteristics. A NAMUR terminal strip with external 24 V stand-by power adds practical integration value, making the unit a strong choice for industrial drive systems.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo