RD51.1-5N-011-L-D1-FW Bosch Rexroth Indramat
MPN: R911200376
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat RD51.1-5N-011-L-D1-FW is a drive controller from the RD 500 Drive Controllers series, designed with a voltage range of 500 V and accepts a three-phase AC supply. It uses forced air cooling and features U/f curve control. The controller includes a NAMUR terminal strip, 24 V external stand-by power, and does not have a built-in brake chopper.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The RD51.1-5N-011-L-D1-FW is a drive controller produced by Bosch Rexroth Indramat for the RD 500 Drive Controllers series. In a typical automation cell, this unit sits between the incoming AC supply and an induction motor, shaping voltage and frequency so pumps, fans, or material-handling axes can run at commanded speeds. Its flexible configuration and clear diagnostics make it suitable for retrofit situations where cabinet space and existing wiring conventions limit how much of the surrounding hardware can be changed.
Motor regulation relies on U/f curve control, so the output frequency follows a predefined voltage-to-frequency ratio that helps preserve magnetic flux during acceleration and load changes. Power enters the device through a three-phase AC converter line section rated for up to 500 V, giving it headroom for 460 V utility grids and normal supply variation. Internal components are kept within their thermal limits by forced air cooling, and the heat sink fins are flushed by an integrated fan that exhausts through the top of the enclosure. Deceleration energy cannot be dissipated inside the unit because it is supplied without a built-in brake chopper; if regenerative braking is required, an external chopper or resistor bank must be added to the DC link.
This model follows design generation 1, so its mounting dimensions match the earliest RD 500 frames. Field wiring lands on a NAMUR terminal strip, allowing the same screw-clamp connection style commonly used in process-control panels. Backup logic power arrives from an auxiliary source, and the control board remains active through an external 24 V standby power feed that supports parameter retention during line outages. Application-specific functions or language files are provided through a separate firmware subposition.
Frequently Asked Questions about RD51.1-5N-011-L-D1-FW:
Q: What voltage range does the RD51.1-5N-011-L-D1-FW drive controller support?
A: The RD51.1-5N-011-L-D1-FW operates with a voltage range of 500 V.
Q: What control type is featured in the RD51.1-5N-011-L-D1-FW?
A: This model uses U/f curve control for its motor drive operations.
Q: How is the RD51.1-5N-011-L-D1-FW drive controller cooled?
A: The RD51.1-5N-011-L-D1-FW uses forced air cooling to maintain its operating temperature.
Q: Is a brake chopper included in the RD51.1-5N-011-L-D1-FW drive controller?
A: This unit does not include a built-in brake chopper.
Q: What external functions are available on the RD51.1-5N-011-L-D1-FW?
A: The RD51.1-5N-011-L-D1-FW features a NAMUR terminal strip and allows for 24 V stand-by power via external connection.