RD51.1-5N-007-L-D1-FW Bosch Rexroth Indramat
MPN: R911200359
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat RD51.1-5N-007-L-D1-FW is a drive controller from the RD 500 Drive Controllers series. It features U/f curve control, a rated power of 7.5 kW, and operates on a 500 V converter 3-phase AC supply. The unit includes a NAMUR terminal strip, external 24 V stand-by power, and uses forced air cooling.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The RD51.1-5N-007-L-D1-FW is a drive controller manufactured by Bosch Rexroth Indramat within the RD 500 Drive Controllers series. It occupies the power stage of an automation cabinet, taking three-phase input and modulating the output frequency so that standard asynchronous motors can be matched to load requirements. By scaling voltage and frequency together, the unit supports variable-speed material transport, fluid handling, and similar processes that need dependable electrical power conversion and stable motor control. The cabinet-mounted format keeps the power electronics in a central enclosure and lets the motor be selected according to the mechanical load.
For machines rated at up to 7.5 kW, the controller provides continuous operation within its specified line window of 500 V. Its front end uses Converter 3 x AC, so the rectifier section is designed for symmetrical three-phase mains and distributes loading across all phases. Motor flux is regulated through U/f curve control, which keeps the voltage-to-frequency ratio constant so torque remains stable from low speed to base speed. Heat produced by the power semiconductors is removed by forced air cooling; the integrated fan moves cabinet air across an internal heat sink and helps keep semiconductor junction temperatures within a safe operating range during repeated acceleration or deceleration cycles.
Operation does not rely on dynamic braking hardware because the model is supplied without built-in brake chopper, so regenerative energy must be handled by an external resistor or by the driven machine. It is part of design generation 1 and includes a NAMUR terminal strip for interface wiring. The controller can remain energized by a 24 V auxiliary source for fieldbus communication or encoder referencing during main power loss, which allows control functions to stay available when the main supply is off. It uses firmware ordered as a separate subposition.
Frequently Asked Questions about RD51.1-5N-007-L-D1-FW:
Q: What is the rated power capacity of the RD51.1-5N-007-L-D1-FW controller?
A: The RD51.1-5N-007-L-D1-FW drive controller provides a rated power output of 7.5 kW.
Q: What supply type is specified for the RD51.1-5N-007-L-D1-FW drive controller?
A: This drive controller uses a three-phase AC converter supply type.
Q: What voltage range does the RD51.1-5N-007-L-D1-FW support?
A: The RD51.1-5N-007-L-D1-FW operates with a voltage range of 500 V.
Q: Does the RD51.1-5N-007-L-D1-FW have a built-in brake chopper?
A: A built-in brake chopper is not included with this model.
Q: What cooling method is used in the RD51.1-5N-007-L-D1-FW drive controller?
A: Forced air cooling is used for thermal management in this device.