RD51.1-5N-005-L-V1-FW Bosch Rexroth Indramat
MPN: R911200373
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat RD51.1-5N-005-L-V1-FW is a drive controller in the RD 500 Drive Controllers series. It features U/f curve control and forced air cooling, with a rated power of 5.5 kW and a 500 V voltage range. The controller is designed for operation with a 3-phase AC converter and does not include a built-in brake chopper.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The RD51.1-5N-005-L-V1-FW drive controller is produced by Bosch Rexroth Indramat as part of the RD 500 Drive Controllers series. In an automation cell, this controller converts fixed supply frequency into a variable output for induction motors, allowing conveyor lines, pumps, or machine tools to match speed demands. This lets the motor start more smoothly and respond to process speed changes without the abrupt shock of across-the-line operation. By combining pulse-width modulation with integrated monitoring circuits, the unit supplies the regulated voltage and frequency needed for stable torque during acceleration and deceleration. That operating method also helps reduce mechanical stress on couplings, belts, and other driven components.
The controller delivers a continuous mechanical capability of 5.5 kW. It uses a Converter 3 × AC supply type, and its internal rectifier and DC link support line voltages up to 500 V. Motor excitation is governed by U/f curve control, so the output voltage changes in proportion to frequency to help keep magnetic flux consistent across the operating range. This control method is commonly used with induction motors in applications where dependable speed adjustment is needed over a broad range. Heat produced by the switching devices is removed through forced air cooling, which uses an integrated fan to move ambient air across the heatsink fins and carry heat away from the power section.
The unit is supplied without a built-in brake chopper, so regenerative energy must be handled by an external resistor when rapid deceleration is required. A dedicated input for 24 V standby power keeps the control electronics active during supply interruptions, which helps preserve communication and stored settings during short power losses. This can allow the controller to remain responsive while the main power section is no longer energized. The controller is part of design generation 1, identifying the early RD51 hardware platform used for this model.
Frequently Asked Questions about RD51.1-5N-005-L-V1-FW:
Q: What is the rated power of the RD51.1-5N-005-L-V1-FW drive controller?
A: The RD51.1-5N-005-L-V1-FW has a rated power output of 5.5 kW.
Q: What type of supply does the RD51.1-5N-005-L-V1-FW require?
A: This controller operates on a 3-phase AC converter supply.
Q: What control type is provided by the RD51.1-5N-005-L-V1-FW?
A: The RD51.1-5N-005-L-V1-FW supports U/f curve control for motor operation.
Q: How is the RD51.1-5N-005-L-V1-FW drive controller cooled?
A: The cooling method for this model is forced air cooling.
Q: Does the RD51.1-5N-005-L-V1-FW include a brake chopper?
A: There is no built-in brake chopper included with this device.