RD51.1-5N-004-L-D1-FW Bosch Rexroth Indramat
MPN: R911200394
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat RD51.1-5N-004-L-D1-FW is a drive controller from the RD 500 Drive Controllers series. It features U/f curve control and operates as a converter on a 3-phase AC supply with a voltage range of 500 V. The unit uses forced air cooling and comes without a built-in brake chopper.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The RD51.1-5N-004-L-D1-FW is a drive controller manufactured by Bosch Rexroth Indramat and assigned to the RD 500 Drive Controllers series. Positioned between the plant’s three-phase supply and an induction motor, it modulates voltage and frequency so conveyor lines, pumps, or fan modules can be started, ramped, and stopped under PLC command. Because it follows a scalar philosophy rather than vector feedback, it serves applications that need reliable speed and torque adjustment without the complexity of full servo positioning. It is well suited to general-purpose motor control where steady operation is more important than high-precision axis control.
At the control layer, the unit implements U/f curve control, keeping motor flux stable by matching output voltage to commanded frequency. Internal thermal management relies on forced-air cooling, using an integrated fan to move heat away from the power stage and allowing the device to fit in stacked cabinets with proper airflow. Regenerative energy is not dissipated inside the housing because this model is supplied without a built-in brake chopper, so dynamic braking requires an external resistor package. Line power enters through a three-phase AC converter front end, and the input circuitry accepts a 500 V input range for operation on factory power systems used in process and material-handling equipment.
Field wiring is organized on a NAMUR terminal strip that separates low-level control signals from high-current conductors and supports intrinsically safe sensor loops. Control electronics remain energized during lockout periods through a dedicated 24 V standby power feed, which keeps communication and parameter memory available when the main bus is not present. The hardware corresponds to design generation 1, matching the mechanical and electrical layout used in early RD 500 units. A separate software package is required for the intended machine function.
Frequently Asked Questions about RD51.1-5N-004-L-D1-FW:
Q: Is there a brake chopper included in the RD51.1-5N-004-L-D1-FW drive controller?
A: The RD51.1-5N-004-L-D1-FW does not have a built-in brake chopper.
Q: What type of control does the RD51.1-5N-004-L-D1-FW drive controller use?
A: This model uses U/f curve control for managing output performance.
Q: How is the RD51.1-5N-004-L-D1-FW drive controller cooled?
A: The cooling method employed is forced air cooling to maintain appropriate operating temperatures.
Q: What is the supply type for the RD51.1-5N-004-L-D1-FW drive controller?
A: The supply type is a 3-phase AC converter, supporting industrial power infrastructures.
Q: What voltage range does the RD51.1-5N-004-L-D1-FW support?
A: The RD51.1-5N-004-L-D1-FW operates within a voltage range of 500 V.