RD51.1-5B-030-D-D1-FW Bosch Rexroth Indramat
Wake Industrial LLC is not an authorized distributor of this product.
MPN: R911200421
Ask for AvailabilityThe Bosch Rexroth Indramat RD51.1-5B-030-D-D1-FW is a drive controller from the RD 500 Drive Controllers series with a rated power of 30 kW and a voltage range of 500 V. It includes a built-in brake chopper, U/f curve control, and plug-through cooler for cooling. This converter operates on 3 phase AC supply and features a NAMUR terminal strip with external 24 V stand-by power.
Internal Product Review
The RD51.1-5B-030-D-D1-FW is a Bosch Rexroth Indramat drive controller with 30 kW rated power and a 500 V voltage range. U/f curve control and converter 3 x AC supply support stable motor management in demanding drive applications. A built-in brake chopper makes this model a highly capable choice for RD 500 installations.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The RD51.1-5B-030-D-D1-FW belongs to the RD 500 Drive Controllers series manufactured by Bosch Rexroth Indramat. It is a three-phase AC converter that regulates induction motors in plant automation by adjusting stator frequency and voltage according to a preset U/f profile. In pump groups, conveyor sections, and similar systems, the unit serves as the main interface between the mains supply and the motor. It provides open-loop speed control for applications that do not require encoder feedback, and commanded frequency is used to set motor speed during normal operation.
This controller uses U/f curve control, so output voltage increases with frequency to help maintain motor flux during acceleration and load changes. The mains interface accepts 500 V and uses a 3 × AC converter topology that rectifies the incoming supply before generating variable-frequency AC at the output. Continuous output is rated at 30 kW, which suits mid-power fans, pumps, and conveyors that run for long operating periods. Heat from the power section is removed by a plug-through cooler, and this arrangement passes the heat sink through the cabinet wall so most losses are released outside the enclosure. By moving a large share of heat away from the cabinet interior, the layout helps reduce the thermal load on surrounding control components.
A built-in brake chopper absorbs regenerated energy during rapid deceleration, which is useful when rotating loads must slow down quickly without overvoltage at the DC link. The NAMUR terminal strip supports straightforward connection of process interlocks and other control signals commonly used in industrial installations. An external standby input supplies 24 V standby power to the control electronics, allowing communication and status monitoring to remain active when the main power circuit is isolated. The unit is in design generation 1, which identifies the hardware generation used for this controller.