RD51.1-5B-011-D-D1-FW Bosch Rexroth Indramat
MPN: R911200809
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat RD51.1-5B-011-D-D1-FW is a drive controller from the RD 500 Drive Controllers series. It supports a voltage range of 500 V and uses U/f curve control, with a built-in brake chopper and a plug-through cooler for cooling. The unit includes a NAMUR terminal strip and supports external 24 V stand-by power.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The RD51.1-5B-011-D-D1-FW belongs to the RD 500 Drive Controllers series produced by Bosch Rexroth Indramat. It is a drive controller intended to regulate three-phase induction motors in automated machinery by adjusting voltage and frequency according to a preset curve. Within a cabinet, the unit acts as the interface between the plant's AC supply and the motor, providing regulated power so conveyors, pumps, and process lines can run at the speed requested by a supervisory PLC. Because the output frequency is controlled electronically, the drive can match motor speed to changing process demand without mechanical throttling or frequent line switching.
The controller includes a built-in brake chopper, allowing excess regenerative energy from decelerating loads to be dissipated internally without external hardware. Speed regulation follows U/f curve control, helping stator flux and torque remain stable when the motor runs below synchronous speed. Thermal management is handled by a plug-through cooler for units up to 110 kW, with the heat sink extending through the panel so most loss heat is expelled outside the enclosure. This arrangement reduces the amount of heat that must be removed by the cabinet ventilation system. Input power is accepted from a three-phase AC supply, and the DC link created from that rectification supports outputs across the 500 V line class.
This model is identified as Generation 1. Application-specific features depend on separately ordered firmware, which is installed in its own subposition. Field wiring is simplified by a NAMUR terminal strip, which groups low-level signals on a standardized block while high-level power remains on bolt terminals. For emergency or diagnostic scenarios, the logic can stay active through a 24 V standby power input, maintaining parameter memory and allowing communication to remain available when the main supply is locked out. That arrangement also lets monitoring and control circuits stay responsive during brief supply interruptions or controlled shutdown states.
Frequently Asked Questions about RD51.1-5B-011-D-D1-FW:
Q: Does the RD51.1-5B-011-D-D1-FW include a brake chopper?
A: A built-in brake chopper is included with the RD51.1-5B-011-D-D1-FW drive controller.
Q: What type of control does the RD51.1-5B-011-D-D1-FW utilize?
A: This drive controller uses U/f curve control for regulating motor speed.
Q: What cooling method is used on the RD51.1-5B-011-D-D1-FW drive controller?
A: A plug-through cooler is used for cooling on this model, suitable for applications up to 110 kW.
Q: Which design generation does the RD51.1-5B-011-D-D1-FW belong to?
A: The RD51.1-5B-011-D-D1-FW is from design generation 1.
Q: What supply type and voltage range are supported by the RD51.1-5B-011-D-D1-FW?
A: This unit accepts a 3-phase AC supply and operates within a 500 V voltage range.