RD51.1-5B-007-L-D1-FW Bosch Rexroth Indramat
Wake Industrial LLC is not an authorized distributor of this product.
MPN: R911200400
Ask for AvailabilityThe Bosch Rexroth Indramat RD51.1-5B-007-L-D1-FW is a drive controller from the RD 500 Drive Controllers series. It features a built-in brake chopper, U/f curve control, and operates with a rated power of 7.5 kW. The controller uses forced air cooling and supports a voltage range of 500 V on a 3-phase AC converter supply.
Internal Product Review
The RD51.1-5B-007-L-D1-FW is a Bosch Rexroth Indramat drive controller designed for converter 3 x AC operation at 7.5 kW. U/f curve control and forced air cooling support stable drive behavior and dependable thermal management in demanding installations. The built-in brake chopper adds practical braking capability, making this controller a strong RD 500 drive solution.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The RD51.1-5B-007-L-D1-FW is a drive controller manufactured by Bosch Rexroth Indramat for the RD 500 Drive Controllers series. Installed in a control cabinet, it converts fixed three-phase line power into a variable output that governs standard AC motors used in material-handling cells, packaging lines, and other automated equipment. By adjusting frequency and voltage, the device delivers speed regulation and soft-start capability for a wide range of general-purpose drive tasks. This operating principle makes the unit appropriate for equipment where smooth speed changes and stable running are more important than rapid positioning response.
Motor behavior is set through U/f curve control, a method that maintains constant air gap flux while the output frequency changes and provides dependable open-loop regulation. The inverter handles a continuous mechanical load of 7.5 kW, matching medium-duty conveyor, fan, and pump applications. Its input section uses a 3 x AC converter input arrangement that connects directly to plant feeders. Power components are sized for a nominal line window around 500 V, which supports operation on common 460 to 525 V networks without additional hardware. Heat generated in the switching devices is removed by forced air cooling, and the internal fan must remain unobstructed so the controller can maintain its rated output.
Rapid deceleration energy is dissipated by the integrated built-in brake chopper, which diverts surplus DC-link voltage to an external resistor and helps prevent overvoltage faults. Control wiring terminates on the standardized NAMUR terminal strip, simplifying integration of run commands, fault reset, and setpoint signals. A dedicated external 24 V standby power feed keeps logic circuits active when the main bus is isolated. The design version is 1, which matches first-generation option cards and mounting patterns. Separate control power also allows the logic section to remain available while the main power section is turned off.