The Bosch Rexroth Indramat RD51.1-4N-315-F-V1-FW is a drive controller in the RD 500 Drive Controllers series, designed with forced air cooling and integrated liquid circulation. It operates with a rated power of 315 kW on a 3-phase AC supply, supporting a voltage range of 380 to 480 V and an integrated mains filter. This controller features U/f curve control and does not have a built-in brake chopper.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The RD51.1-4N-315-F-V1-FW belongs to the RD 500 Drive Controllers series from Bosch Rexroth Indramat. It is a high-capacity drive controller for regulating large induction motors in automated production cells, conveying systems, and process equipment. By converting incoming three-phase mains power into controlled output pulses, the unit adjusts motor speed to match load demand while reducing unnecessary energy use. This kind of control supports variable-speed operation, smoother starts, and better process consistency on heavy-duty machinery. Its design suits installations that require stable motor response during continuous operation and changing load conditions.

In operation, the controller uses a three-phase AC converter supply with an input range of 380 to 480 V. The allowable mains variation is ±10%, which helps the unit remain operational when plant voltage shifts within normal industrial limits. Inside that window, the drive can deliver up to 315 kW to the connected motor group, making it suitable for high-power applications. Control is based on U/f curve control, which keeps the voltage-to-frequency ratio consistent so motor flux remains stable through the speed range. This control method is commonly used where dependable open-loop speed regulation is required and very complex feedback hardware is not necessary.

Thermal management uses forced-air cooling with integrated liquid circulation, combining internal airflow with a closed coolant loop to carry heat away from power components under sustained load. The unit comes without a built-in brake chopper, so braking energy from rapid deceleration must be handled by external equipment when the application demands it. An integrated mains filter helps reduce conducted interference on the supply side and supports cleaner electrical operation in shared power systems. The control section can remain energized from external 24 V standby power, allowing monitoring and parameter access when the main power stage is switched off. This arrangement helps preserve communication and setup access during service states without energizing the motor output stage.

Brake Chopper
Without built-in brake chopper
Control Type
U/f curve control
Cooling Type
Forced air cooling integrated liquid circulation
Design Generation
1
Firmware Note
Firmware must be ordered as separate subposition
Functions
24 V stand-by power, external
Mains Filter
Integrated
Product Type
Drive Controller
Rated Power
315 kW
Supply Type
Converter 3 x AC
Tolerance
±10 %
Voltage Range
380 to 480 V
  • RD5114N315FV1FW
  • RD51 1 4N 315 F V1 FW
  • rd51.1-4n-315-f-v1-fw

Frequently Asked Questions about RD51.1-4N-315-F-V1-FW:

Q: What is the rated power output of the RD51.1-4N-315-F-V1-FW drive controller?

A: The RD51.1-4N-315-F-V1-FW drive controller has a rated power of 315 kW.

Q: What input voltage range does the RD51.1-4N-315-F-V1-FW accept?

A: This model supports a voltage range of 380 to 480 V to match various industrial power supplies.

Q: What cooling method does the RD51.1-4N-315-F-V1-FW utilize?

A: The RD51.1-4N-315-F-V1-FW features forced air cooling with integrated liquid circulation.

Q: Is there a mains filter included in the RD51.1-4N-315-F-V1-FW?

A: This drive controller is equipped with an integrated mains filter.

Q: What control method is used by the RD51.1-4N-315-F-V1-FW drive controller?

A: The RD51.1-4N-315-F-V1-FW operates with U/f curve control.


Internal Product Review

  • ‘‘The RD51.1-4N-315-F-V1-FW is a Bosch Rexroth Indramat drive controller with U/f curve control and a 315 kW rated power. Integrated liquid-circulation forced air cooling and an integrated mains filter support stable performance in demanding drive applications. Converter 3 x AC operation across 380 to 480 V makes the controller a strong choice for high-power industrial systems.’’