RD51.1-4N-110-L-NN-FW/S111 Bosch Rexroth Indramat
MPN: R911200704
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat RD51.1-4N-110-L-NN-FW/S111 is a drive controller from the RD 500 Drive Controllers series, supporting a voltage range of 380 to 480 V with a rated power of 110 kW. It features U/f curve control, forced air cooling, and an integrated mains filter, and is designed for use with a converter 3 x AC supply. This model is provided without a built-in brake chopper and accommodates a tolerance of plus or minus 10 percent.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The RD51.1-4N-110-L-NN-FW/S111 is a drive controller produced by Bosch Rexroth Indramat for the RD 500 Drive Controllers series. The unit converts fixed mains power into adjustable three-phase output so asynchronous motors in transport lines, mixers, and fan arrays can maintain stable torque and speed as operating demand changes. It is intended for cabinet-based installations where coordinated motor control is required across continuous industrial processes. In a modular drive lineup, it mounts beside rectifier and line components, communicates with higher-level PLCs through standard bus hardware, and stores parameter sets for acceleration ramps, current limits, and trip thresholds.
The controller accepts an input range of 380 to 480 V and tolerates line variation of ±10 % without derating. Its power bridge is rated for 110 kW, and motor behavior is regulated through U/f curve control to match output voltage and frequency during speed changes. Heat from the power section is removed by forced air cooling, so the cabinet must provide steady airflow for continuous operation. This control method is commonly used with induction motors that need predictable speed response and dependable operation under changing mechanical load.
As a 3 x AC converter, the RD51.1 module delivers variable-frequency output for industrial motor control. It is supplied without a built-in brake chopper, so braking energy must be handled by external equipment when the application has high deceleration demand. The mains filter is integrated, which helps reduce conducted interference on the supply connection, and the application section is not equipped with option cards. The unit is supplied without operating software loaded, so the required software must be ordered separately to match the intended control task.
Frequently Asked Questions about RD51.1-4N-110-L-NN-FW/S111:
Q: What is the rated power output of the RD51.1-4N-110-L-NN-FW/S111 drive controller?
A: The RD51.1-4N-110-L-NN-FW/S111 drive controller provides a rated power output of 110 kW.
Q: What voltage range does the RD51.1-4N-110-L-NN-FW/S111 support?
A: It operates with a voltage range from 380 to 480 V, suitable for industrial power systems.
Q: Does the RD51.1-4N-110-L-NN-FW/S111 include an integrated mains filter?
A: This model features integrated mains filtering for reduced electrical interference.
Q: What type of cooling system is used in the RD51.1-4N-110-L-NN-FW/S111 drive?
A: Forced air cooling is used to manage thermal conditions in the RD51.1-4N-110-L-NN-FW/S111.
Q: What control method does the RD51.1-4N-110-L-NN-FW/S111 drive controller use for motors?
A: The RD51.1-4N-110-L-NN-FW/S111 uses U/f curve control for motor management.