RD51.1-4N-018-L-DF-FW Bosch Rexroth Indramat
Wake Industrial LLC is not an authorized distributor of this product.
MPN: R911200733
Ask for AvailabilityThe Bosch Rexroth Indramat RD51.1-4N-018-L-DF-FW is a drive controller from the RD 500 Drive Controllers series with a rated power of 18.5 kW and operates on a voltage range of 380 to 480 V AC. It features U/f curve control, integrated mains filter, and forced air cooling, and includes a NAMUR terminal strip with 24 V stand-by power external.
Internal Product Review
The RD51.1-4N-018-L-DF-FW is a Bosch Rexroth Indramat drive controller with 18.5 kW rated power. U/f curve control and forced air cooling give the unit stable speed regulation and dependable thermal performance in continuous-duty applications. An integrated mains filter supports cleaner installation, and the 380 to 480 V range makes the controller especially practical for standard industrial power systems.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The RD51.1-4N-018-L-DF-FW is a drive controller manufactured by Bosch Rexroth Indramat within the RD 500 Drive Controllers series. In an automation cell, it links the incoming three-phase mains to an induction motor and regulates speed and torque so conveyors, mixers, or pumps follow programmed commands. By modulating the output frequency and voltage, the unit supplies the motor with the electrical profile requested by the programmable logic controller. This makes it suitable for variable-speed industrial processes that need stable motor control across changing load conditions.
This controller delivers a rated power of 18.5 kW, which is suitable for medium-sized production machinery. It accepts line supplies in the 380 to 480 V range and is built as a 3 x AC converter, meaning it rectifies a three-phase input before generating a variable AC output. Speed regulation is based on U/f curve control, so the output voltage follows a preset relationship to frequency and helps maintain proper magnetizing current at low speed. Internal heat is removed through forced-air cooling, which supports continuous duty at full load when cabinet airflow is maintained. The power stage and control boards are built to design generation 1, and the line fluctuation tolerance remains within the stated operating window.
An integrated mains filter suppresses conducted emissions, while the unit is supplied without a built-in brake chopper, so dynamic braking requires an external resistor when rapid stops are needed. The permissible input swing remains within ±10%, and the front panel includes a NAMUR terminal strip with external 24 V stand-by power so connected field devices can remain energized during a mains interruption. Current feedback from the U6, V6, and W6 links helps the control board monitor filter loading without requiring additional transducers. This arrangement supports stable supervision of the power section during normal operation.