RD51.1-4N-007-L-DF-FW Bosch Rexroth Indramat
Wake Industrial LLC is not an authorized distributor of this product.
MPN: R911200674
The Bosch Rexroth Indramat RD51.1-4N-007-L-DF-FW is a drive controller from the RD 500 Drive Controllers series with a rated power of 7.5 kW and a voltage range of 380 to 480 V. It features forced air cooling, U/f curve control, and comes without a built-in brake chopper. The controller has an integrated mains filter and accepts a converter 3 x AC supply.
Internal Product Review
The RD51.1-4N-007-L-DF-FW is a Bosch Rexroth Indramat drive controller with U/f curve control and forced air cooling. Converter 3 x AC supply compatibility and a 380 to 480 V input range support dependable integration across standard industrial power systems. An integrated mains filter and 7.5 kW rated power make the controller a strong choice for stable mid-range drive applications.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The RD51.1-4N-007-L-DF-FW is a drive controller produced by Bosch Rexroth Indramat as part of the RD 500 Drive Controllers series. Designed for cabinet installation, the unit modulates inverter output to regulate induction-motor speed throughout automated material-handling or process lines. By adjusting the motor voltage and frequency, it supports coordinated movement, energy savings, and consistent torque delivery in conveyor sections, pumps, and mixers commonly found in manufacturing cells.
It is powered from a three-phase AC converter supply and accepts line voltages from 380 to 480 V; the controller remains functional while line variation stays within a margin of ±10 %. Within this window, it can deliver a continuous shaft output of up to 7.5 kW, matching medium-frame motors used on small presses or fan drives. Speed regulation is achieved through U/f curve control, so the ratio between output voltage and frequency remains fixed, keeping magnetic flux at the desired level during ramp-up or load changes. Internally, the device reports phase current via the U6, V6, and W6 monitor points, allowing the supervisory PLC to track filter performance and detect imbalance.
Thermal management relies on forced air cooling; a top-mounted blower moves cabinet air across the heat sink to maintain semiconductor junction temperatures. Because the controller is supplied without a built-in brake chopper, any regenerative braking energy must be handled by an external resistor or returned to the mains. Line disturbance is minimized by the integrated mains filter, which suppresses conducted emissions and supports compliance with industrial EMC limits. For safety interlocks and emergency power support, a NAMUR terminal strip with an external 24 V standby source is available. The hardware belongs to design generation 1.