The Bosch Rexroth Indramat RD51.1-4N-001-L-V1-FW is a drive controller from the RD 500 Drive Controllers series. It uses U/f curve control and operates on a voltage range of 380 to 480 Volts. This unit features forced air cooling, an integrated mains filter, and accepts a 3-phase AC supply.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The RD51.1-4N-001-L-V1-FW is a drive controller produced by Bosch Rexroth Indramat and belongs to the RD 500 Drive Controllers series. As a converter module, it regulates three-phase induction motors by translating fixed mains power into variable frequency and voltage for industrial automation conveyors, pumps, and material-handling axes. The unit fits into multi-axis cabinets where fieldbus drives are coordinated, permitting scalar speed regulation in applications that do not require full vector feedback.
Speed reference is processed through U/f curve control, so the output voltage follows a preset ratio to the commanded frequency for straightforward scalar operation. Thermal management relies on forced air cooling, and the housing channels cabinet airflow to remove heat from the power section while keeping semiconductor junctions within rated limits. An integrated mains filter attenuates conducted emissions, allowing the converter to connect to plant networks without an added line choke. The supply interface uses a three-phase AC converter configuration that draws balanced power from three-phase sources. Acceptable input spans 380 to 480 V, which covers common 400 V and 460 V grids used in North American and European facilities.
Line fluctuations up to a ±10% tolerance are accepted, helping prevent nuisance trips when generators start or heavy loads switch. The unit is design generation 1, so it uses matching option cards and mounting dimensions. Control electronics can remain active through the external 24 V standby power function, enabling fieldbus communication and diagnostics even when the main contactor is open. The drive requires application software ordered separately. Because the controller does not include a built-in brake chopper, an external chopper is required if rapid dynamic braking of the motor is needed.
Frequently Asked Questions about RD51.1-4N-001-L-V1-FW:
Q: What control method does the RD51.1-4N-001-L-V1-FW drive controller use?
A: The RD51.1-4N-001-L-V1-FW operates using U/f curve control for motor management.
Q: What type of cooling is used in the RD51.1-4N-001-L-V1-FW drive controller?
A: This model features forced air cooling, which helps maintain optimal operating temperatures.
Q: Is a mains filter included in the RD51.1-4N-001-L-V1-FW drive controller?
A: A mains filter is integrated into the RD51.1-4N-001-L-V1-FW, reducing electrical noise from the power source.
Q: What supply voltage range does the RD51.1-4N-001-L-V1-FW support?
A: The RD51.1-4N-001-L-V1-FW operates on a supply voltage range of 380 to 480 V with a tolerance of ±10%.
Q: Does the RD51.1-4N-001-L-V1-FW include a brake chopper?
A: This drive controller does not have a built-in brake chopper.