RD51.1-4N-001-L-D1-FW Bosch Rexroth Indramat
MPN: R911200547
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat RD51.1-4N-001-L-D1-FW is a drive controller from the RD 500 Drive Controllers series. It uses U/f curve control and operates on a voltage range of 380 to 480 V with a ±10 percent tolerance. This model features forced air cooling, an integrated mains filter, and a NAMUR terminal strip with external 24 V standby power.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The RD51.1-4N-001-L-D1-FW is a drive controller manufactured by Bosch Rexroth Indramat and belongs to the RD 500 Drive Controllers series. It functions as the closed-loop interface between the plant’s central PLC and a three-phase induction motor, shaping voltage and frequency so that conveyor speed, pump flow, or spindle rotation follows programmed setpoints. Installed inside electrical cabinets, the unit forms part of larger converter groups that coordinate motion sequences in automated production lines.
This controller accepts a mains range of 380 to 480 V and is supplied through a three-phase AC converter front end, meaning it draws power evenly from all three phases of the factory supply. A permissible line variation of ±10 % helps prevent nuisance trips when utility voltage drifts during load peaks or generator changeovers. Motor magnetization is handled with U/f curve control; by maintaining a constant voltage-to-frequency ratio, the flux in the stator remains stable from zero hertz up to the rated frequency, allowing predictable torque across the speed range. An integrated mains filter attenuates conducted emissions, so additional cabinet filters are normally unnecessary for EMC compliance.
Thermal management relies on forced-air cooling, and a dedicated fan moves air across the heat sinks so the controller can be mounted side by side with minimal spacing. Dynamic braking hardware is omitted, so the unit operates without a built-in brake chopper, and excess regenerative energy must be handled by an external resistor or fed back to the grid. Field wiring is streamlined by the NAMUR terminal strip, and emergency logic can be kept active through the external 24 V standby power input. The unit is in design generation 1, matching the electrical characteristics used across other RD 500 modules in multi-axis installations.
Frequently Asked Questions about RD51.1-4N-001-L-D1-FW:
Q: What input voltage range does the RD51.1-4N-001-L-D1-FW drive controller support?
A: The RD51.1-4N-001-L-D1-FW supports a voltage range of 380 to 480 V for input supply.
Q: Does the RD51.1-4N-001-L-D1-FW include a mains filter?
A: This drive controller is equipped with integrated mains filtering for compliance and signal quality.
Q: How is the RD51.1-4N-001-L-D1-FW drive controller cooled?
A: The RD51.1-4N-001-L-D1-FW uses forced air cooling to maintain ideal operating temperatures.
Q: What control method is utilized by the RD51.1-4N-001-L-D1-FW?
A: It operates using U/f curve control, providing voltage-to-frequency output for motor control.
Q: Is a brake chopper included in the RD51.1-4N-001-L-D1-FW drive controller?
A: This model does not have a built-in brake chopper, so external braking solutions may be required.