RD51.1-4N-001-L-C1-FW Bosch Rexroth Indramat
Wake Industrial LLC is not an authorized distributor of this product.
MPN: R911200554
Ask for AvailabilityThe Bosch Rexroth Indramat RD51.1-4N-001-L-C1-FW is a drive controller from the RD 500 Drive Controllers series. It features U/f curve control, forced air cooling, and runs on a three-phase AC supply with a voltage range of 380 to 480 V. The unit includes an integrated mains filter and provides 24 V external stand-by power.
Internal Product Review
The RD51.1-4N-001-L-C1-FW is a Bosch Rexroth Indramat drive controller designed for converter 3 x AC input and 380 to 480 V operation. U/f curve control and forced air cooling support stable drive behavior and dependable thermal management in standard industrial duty. The integrated mains filter adds practical installation value, and the RD 500 unit stands out as a strong choice for efficient cabinet integration.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The RD51.1-4N-001-L-C1-FW is a drive controller manufactured by Bosch Rexroth Indramat within the RD 500 Drive Controllers series. As a converter-based unit, it provides variable-speed regulation for three-phase induction motors used in conveyors, pumps, and similar automated machinery. By modulating the supplied voltage and frequency, the controller optimizes motor torque and energy consumption across a broad range of industrial tasks. In automated systems, this allows motor output to follow changing process demand while reducing abrupt mechanical loading on belts, impellers, and other driven components.
This model accepts a line voltage of 380–480 V and uses U/f curve control, a method that helps keep the motor's magnetic flux nearly constant as speed changes. This control approach suits applications that need stable speed behavior without more complex motor feedback arrangements. Input power is supplied through a three-phase AC converter supply, allowing direct connection to common plant mains. The housing uses forced air cooling, with a built-in fan moving ambient air across internal heat sinks during continuous load cycles. For dynamic braking events, the controller is supplied without a built-in brake chopper, so regenerated energy requires external chopper hardware, and an integrated mains filter helps limit conducted emissions and reduce line-borne interference.
Component tolerances permit operation with a line deviation of ±10% without derating, which supports use on industrial networks with moderate voltage fluctuation. During idle periods, the controller can remain energized by 24 V standby power, keeping monitoring circuits and communication modules active for a quick restart. Internal circuit boards correspond to design generation 1. This generation matches first-generation RD500 option cards and parameter tools, which helps maintain compatibility within the same product platform.