RD51.1-4B-037-L-DF-FW Bosch Rexroth Indramat
Wake Industrial LLC is not an authorized distributor of this product.
MPN: R911200671
Ask for AvailabilityThe Bosch Rexroth Indramat RD51.1-4B-037-L-DF-FW is a drive controller in the RD 500 Drive Controllers series with a rated power of 37 kW. It operates with a voltage range of 380 to 480 V and utilizes a converter for 3-phase AC supply. The controller features a built-in brake chopper, integrated mains filter, and forced air cooling.
Internal Product Review
The RD51.1-4B-037-L-DF-FW is a Bosch Rexroth Indramat drive controller with 37 kW rated power. Forced air cooling and an integrated mains filter support stable operation in demanding converter installations. A built-in brake chopper makes the unit especially capable in 380 to 480 V applications.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The RD51.1-4B-037-L-DF-FW drive controller is manufactured by Bosch Rexroth Indramat and belongs to the RD 500 Drive Controllers series. Installed between a three-phase supply and an induction motor, the unit conditions incoming line power and adjusts output frequency so that conveyors, pumps, or mixers can run at the speed requested by a higher-level PLC. By replacing mechanical throttling with electronic regulation, it can reduce wasted energy while still keeping useful torque available across the operating range. This approach also helps process equipment respond more smoothly to changing load and flow conditions during normal production.
At the electrical interface, the controller delivers a rated output of 37 kW when supplied from 380 to 480 V AC mains. The built-in power stage accepts line variations of ±10 % and maintains motor flux through a scalar U/f curve control method that suits standard cage motors in general-purpose variable-speed applications. A built-in brake chopper diverts regenerative energy to an external resistor during rapid deceleration to help prevent DC-link overvoltage. This arrangement supports controlled stopping of high-inertia loads. The NAMUR terminal strip provides 24 V external standby power for status circuits, and a dedicated feedback path for the current filter at U6, V6, and W6 supports drive diagnostics without auxiliary probes.
Thermal management relies on forced air cooling, so the heat sink fins must remain clear of obstructions inside the cabinet and airflow must not be blocked by adjacent components. The power stack is fed from a Converter 3 × AC front end, and conducted EMI is reduced by an integrated mains filter that limits high-frequency switching noise returning to the plant grid. Classified as generation 1, the unit uses an established hardware layout for this design and retains the NAMUR I/O and current-filter feedback used for operating status and diagnostic monitoring.