The Bosch Rexroth Indramat RD51.1-4N-015-L-NN-FW-S111 is a drive controller from the RD 500 Drive Controllers series with a rated power of 15.0 kW. This product uses U/f curve control, operates with a voltage range of 380 to 480 V, and is cooled using forced air cooling. It has an integrated mains filter and is designed for converter 3 x AC supply.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The RD51.1-4N-015-L-NN-FW-S111 drive controller is built by Bosch Rexroth Indramat and belongs to the RD 500 Drive Controllers series. Designed for cabinet installation, the unit converts fixed-frequency mains power into a variable output that matches motor requirements. This allows precise speed control, energy savings, and smoother mechanical engagement in automated production cells. It is suitable for cabinet-mounted systems where adjustable motor speed helps reduce shock during starts and stops.

It operates from a three-phase line supply in a 3 x AC converter configuration, and it accepts line voltage from 380 to 480 V. The inverter bridge is sized for a continuous mechanical output of 15.0 kW, so medium-capacity drives can be supported without requiring larger hardware. Input excursions are tolerated within a ±10% tolerance band that helps avoid nuisance trips during normal supply variation. Motor excitation is handled with U/f curve control, which maintains a proportional volts-per-hertz relationship to support stable magnetic flux across the operating speed range. Thermal management relies on forced-air cooling, and internal fans move cabinet air across the heat sinks to limit semiconductor temperature during sustained load. An integrated mains filter attenuates conducted emissions to support use in industrial electrical systems.

The power section is without a built-in brake chopper, so external braking hardware is required when the application returns energy during deceleration. The hardware layout corresponds to design generation 1, which supports compatibility with first-generation option cards and mounting accessories. The software package is ordered as a separate subposition, allowing the controller to be matched to the required fieldbus or application package. No supplemental technology functions are installed, which keeps the configuration focused on standard variable-speed drive tasks.

Brake Chopper
Without built-in brake chopper
Control Type
U/f curve control
Cooling Type
Forced air cooling
Design Generation
1
Firmware Note
Firmware must be ordered as separate subposition
Functions
Not equipped
Mains Filter
Integrated
Product Type
Drive Controller
Rated Power
15.0 kW
Supply Type
Converter 3 x AC
Tolerance
±10 %
Voltage Range
380 to 480 V
  • RD 51.1-4N-015-L-NN-FW/S111
  • RD51-1-4N-015-L-NN-FW/S111
  • RD51.1 4N 015 L NN FW/S111
  • RD51.1-4N-015-L-NN-FW/S111
  • RD51.1-4N-O15-L-NN-FW/S111
  • RD5114N015LNNFWS111
  • rd51.1-4n-015-l-nn-fw-s111
  • RD51.1-4N-15-L-NN-FW-S111
  • rd5114n015lnnfws111
  • RDS1.1-4N-015-L-NN-FW-S111
  • RD5I.1-4N-015-L-NN-FW-S111
  • RD51.I-4N-015-L-NN-FW-S111
  • RD51.1-4N-O15-L-NN-FW-S111
  • RD51.1-4N-0I5-L-NN-FW-S111
  • RD51.1-4N-01S-L-NN-FW-S111
  • RD51.1-4N-015-L-NN-FW-5111
  • RD51.1-4N-015-L-NN-FW-SI11
  • RD51.1-4N-015-L-NN-FW-S1I1
  • RD51.1-4N-015-L-NN-FW-S11I
  • RDSI.I-4N-OIS-L-NN-FW-5III
  • RD51.14N-015-L-NN-FW-S111
  • RD51.1-4N015-L-NN-FW-S111
  • RD51.14N015-L-NN-FW-S111
  • RD51.1-4N-015L-NN-FW-S111
  • RD51.14N-015L-NN-FW-S111

Frequently Asked Questions about RD51.1-4N-015-L-NN-FW-S111:

Q: What is the rated power output of the RD51.1-4N-015-L-NN-FW-S111 drive controller?

A: The RD51.1-4N-015-L-NN-FW-S111 drive controller delivers a rated power output of 15.0 kW.

Q: What type of control strategy is used by the RD51.1-4N-015-L-NN-FW-S111?

A: This drive controller implements U/f curve control for motor operation.

Q: How is the RD51.1-4N-015-L-NN-FW-S111 drive controller cooled?

A: The RD51.1-4N-015-L-NN-FW-S111 uses forced air cooling for temperature management.

Q: Is an integrated mains filter included in the RD51.1-4N-015-L-NN-FW-S111 model?

A: The mains filter is integrated into this drive controller, reducing the need for external components.

Q: What is the supply voltage range and tolerance for the RD51.1-4N-015-L-NN-FW-S111?

A: The RD51.1-4N-015-L-NN-FW-S111 operates with a supply voltage range from 380 to 480 V (3-phase AC) and a tolerance of ±10%.


Internal Product Review

  • ‘‘The RD51.1-4N-015-L-NN-FW-S111 is a Bosch Rexroth Indramat drive controller that offers U/f curve control and delivers a rated power of 15.0 kW for demanding industrial drive applications. Forced air cooling and an integrated mains filter ensure continuous, efficient operation in harsh environments. The model stands out for stable performance and reliable converter supply across a 380 to 480 V voltage range.’’