RAC 2.3-200-460-APS-W1 Bosch Rexroth Indramat
MPN: R911262840
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat RAC 2.3-200-460-APS-W1 is an AC main spindle drive controller from the RAC Spindle Drive Controllers series. It features a rated connection voltage range of 3 x AC 400 V at 50 Hz or 3 x AC 460 V and a rated current of 200 Amps. This controller offers a high-resolution INDRAMAT encoder for spindle feedback and includes a built-in fan for cooling.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The RAC 2.3-200-460-APS-W1 spindle drive controller is manufactured by Bosch Rexroth Indramat and belongs to the RAC Spindle Drive Controllers series. As an AC main spindle drive controller, it interfaces with CNC or PLC equipment to regulate torque and rotational speed on machine-tool spindles, enabling repeatable cutting, milling, or grinding cycles in automated production cells. Built-in power electronics, encoder processing, and cooling hardware make the unit a self-contained axis module for demanding duty cycles. Its role is to provide stable spindle control where accurate speed regulation and responsive torque delivery are required during machining.
This model operates from a three-phase supply of 3 × AC 400 V, 50 Hz, ±15% or 3 × AC 460 V and can deliver a continuous line current of 200 A to the spindle motor. Heat generated by the switching devices is removed by a built-in blower, so external cooling ducts are not required. The speed reference is an analog (±10 V) signal, which allows direct connection to conventional motion controllers used in machine tools and similar automation systems. For diagnostics and parameter access, an RS 232-C serial interface is available, allowing a direct data link without opening the enclosure.
An additional encoder input for spindle feedback accepts position data from the motor’s own high-resolution INDRAMAT encoder, supporting closed-loop vector control across the speed range. Field wiring to the logic layer is grouped on connector X4 with 9 poles, which combines control-voltage, reference, and monitor lines in a single plug. The unit is supplied without an additional bleeder, so regenerative energy is handled by the existing internal circuitry whenever operating conditions allow. The controller is Version 3 and Series 2, which places it within a later revision of this spindle-drive platform.
Frequently Asked Questions about RAC 2.3-200-460-APS-W1:
Q: What is the rated current for the RAC 2.3-200-460-APS-W1 controller?
A: This spindle drive controller supports a rated current of 200 A, which allows it to power high-capacity spindle motors.
Q: What connection voltage does the RAC 2.3-200-460-APS-W1 support?
A: The RAC 2.3-200-460-APS-W1 accepts a rated connection voltage of 3 x AC 400 V at 50 Hz, plus or minus 15%, or 3 x AC 460 V for flexible installation.
Q: How is the RAC 2.3-200-460-APS-W1 spindle drive controller cooled?
A: This model is cooled by an internal blower or built-in fan, ensuring proper heat dissipation during operation.
Q: What type of additional encoder input is available on the RAC 2.3-200-460-APS-W1?
A: The RAC 2.3-200-460-APS-W1 features an additional encoder input specifically for spindle feedback integration.
Q: What type of speed command input does the RAC 2.3-200-460-APS-W1 use?
A: The speed command for this controller is analog, with a range of +/- 10 V for precise spindle speed control.