RAC 2.2-200-380-A00-W1/S001 Bosch Rexroth Indramat
MPN: R911255606
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat RAC 2.2-200-380-A00-W1/S001 is an AC Main Spindle Drive Controller from the RAC Spindle Drive Controllers series. This controller features a rated connection voltage of 3 x AC 400 V at 50-60Hz and a rated current of 200 Amps. It is equipped with an internal blower for cooling and uses an X4, 9-pole interface terminal with an analog speed command input of +/- 10 V.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The RAC 2.2-200-380-A00-W1/S001 spindle drive controller is manufactured by Bosch Rexroth Indramat and belongs to the RAC Spindle Drive Controllers series. As an AC main spindle drive controller, it forms the power and regulation stage between the CNC and the motor, supplying controlled three-phase energy so that machining spindles reach commanded speed and torque values in industrial automation lines. The unit regulates motor current and speed in response to CNC commands, which helps maintain stable spindle behavior during cutting processes. It is suited to machine tools that require controlled acceleration, deceleration, and continuous spindle duty.
This controller operates with a continuous line load of 200 A, so supply conductors, fuses, and contactors must be sized for that current. It connects to a three-phase mains of 3 x AC 400 V, and its power electronics are synchronized to grids in the 50–60 Hz range, allowing installation in most industrial plants without an additional transformer. Motion commands arrive as an analog (±10 V) velocity reference, which the internal control loop converts into torque-producing current for spindle regulation. Using this voltage reference format allows direct connection to common CNC analog command outputs. Heat generated by the IGBT stack is removed through an internal blower, eliminating the need for external ducting and helping the drive maintain stable operating temperature during sustained use.
Control wiring is landed on interface terminal X4, 9 poles, separating low-level I/O from power conductors and simplifying cabinet layouts. Separating the control section from the power section can also help reduce interference in command wiring. The product is Series 2 and Version 2. Regenerative braking energy is handled by the standard bus capacitors because the unit is supplied without an additional bleeder, so applications that demand extended dynamic braking may require an external resistor bank. It is also delivered without an additional encoder input, so any secondary position transducer must be processed by the machine controller rather than the drive itself.
Frequently Asked Questions about RAC 2.2-200-380-A00-W1/S001:
Q: What is the rated current specification of the RAC 2.2-200-380-A00-W1/S001 spindle drive controller?
A: The RAC 2.2-200-380-A00-W1/S001 supports a rated current of 200 A for main spindle drive operation.
Q: What type of speed command input does the RAC 2.2-200-380-A00-W1/S001 accept?
A: This spindle drive controller uses an analogue speed command input of +/- 10 V.
Q: How is the RAC 2.2-200-380-A00-W1/S001 spindle drive controller cooled?
A: Cooling is provided through an internal blower with a built-in fan.
Q: What is the rated connection voltage for the RAC 2.2-200-380-A00-W1/S001?
A: The device operates with a rated connection voltage of 3 x AC 400 V at 50-60Hz.
Q: Does the RAC 2.2-200-380-A00-W1/S001 feature an additional encoder input?
A: There is no additional encoder input included on this model.