The Bosch Rexroth Indramat PST6100.201-L is part of the PST Thyristor Power Units series and is designed for recessed mounting. It features a nominal system current of 130 Amps, a maximum transformer power of 76 kVA, and supports a control supply of 24 V DC. This air cooled unit offers integrated temperature monitoring and a protection rating of IP20.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The PST6100.201-L belongs to the PST Thyristor Power Units series from Bosch Rexroth Indramat. As a thyristor-based power unit, it is installed in automated machinery to modulate AC energy delivered to high-current loads while keeping cabinet wiring simplified. The device fits recessed panels and interfaces with higher-level controls through a PROFIBUS timing channel, allowing synchronized firing commands within complex production cells. This operating method is useful where the machine controller must coordinate power delivery with repeatable process timing, such as in heating or welding applications that depend on controlled phase-angle switching.
The unit draws its control electronics from a 24 V DC auxiliary supply and passes line current through a silicon rectifier bridge that can supply a nominal 130 A to the connected load. When used with matching transformers, it supports up to 76 kVA of apparent power, making it suitable for medium-capacity welding or heating circuits that require substantial current. Internal conduction and switching generate cabinet losses of 70 W, so the design uses forced-air cooling across the heat sinks rather than liquid cooling. Protection against accidental contact is rated at IP20, while an MOV network limits mains surges and integrated sensors monitor internal temperature rise during operation.
Ambient operation is permitted up to 55 °C, provided the incoming cooling air stays below 45 °C and the application follows a maximum duty cycle of 50% to prevent thermal saturation during repeated load pulses. At installation, at least 100 mm of clearance must be left above and below the chassis so the blower path remains unobstructed and warm air can move away from the heat-producing sections. The power terminals accept conductors up to 50 mm², which helps match the current path and keep connection resistance low. The recessed mounting style places the heat-dissipating surfaces flush with the enclosure, supporting straight airflow through the cabinet.
Frequently Asked Questions about PST6100.201-L:
Q: What is the nominal system current rating for the PST6100.201-L thyristor power unit?
A: The PST6100.201-L has a nominal system current of 130 A for standard operation.
Q: What type of overvoltage protection is included in the PST6100.201-L?
A: This unit comes equipped with overvoltage protection using MOV technology.
Q: What cooling method does the PST6100.201-L use?
A: The PST6100.201-L is air cooled to manage heat dissipation during use.
Q: What is the protection rating of the PST6100.201-L thyristor power unit?
A: It is designed with a protection rating of IP20, offering limited protection against solid objects but not against liquids.
Q: What is the maximum transformer power for the PST6100.201-L?
A: The maximum transformer power supported by this unit is 76 kVA.