4.95 based on 202 reviews

🙶 Wake was very helpful in getting us a servo motor and drive for our tube mill line. This was the first tim... 🙷

PSI63C0.772-L2 Bosch Rexroth Indramat

Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat PSI63C0.772-L2 is a medium frequency inverter in the PSI Frequency Inverters series, operating on a mains voltage range of 480 to 690 VAC with a control supply of 24 VDC. It supports a max output current of 800 Amps, nominal system current of 110 Amps, and features air cooling with a cabinet loss of 100 W and a cooling loss of 360 W. The inverter offers an IP20 degree of protection and supports overvoltage protection via MOV.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The PSI63C0.772-L2 is a medium-frequency inverter produced by Bosch Rexroth Indramat for the PSI Frequency Inverters series. In automated production lines, the unit supplies variable medium-frequency power to heating, welding, and similar process loads, acting as an interface between the three-phase mains supply and a tuned work coil or transformer. By modulating current and voltage, it provides accurate energy dosing in response to commands from a process controller or PLC, reducing thermal overshoot and supporting repeatable operation. Its compact design allows installation in a standard industrial control cabinet while leaving space for the required power connections and cooling airflow.

The electrical section accepts a three-phase supply of 480 to 690 VAC at 50/60 Hz, allowing direct connection to compatible high-voltage plant buses. When energized, the converter produces a basic cabinet power loss of 100 W. Semiconductor switching contributes an additional 360 W of heat that must be removed by the cabinet’s air-cooling system. The enclosure has an ingress protection rating of IP20, which protects against accidental contact with internal parts but does not provide protection from dust or water. These electrical and thermal characteristics must be considered when selecting the mounting position, ventilation capacity, and surrounding cabinet equipment.

A control supply of 24 VDC powers the logic circuits and Ethernet-based timer functions. The power stage can conduct up to 800 A during transient demand, while its continuous current rating is 110 A. When paired with a downstream PSG 3100 transformer, the system supports a secondary short-circuit current of 36 kA for fault-clearing operation. Because the assembly is air-cooled, the incoming cooling air must not exceed 45 °C, while the surrounding ambient temperature may reach 55 °C without derating. A clearance of 100 mm around the cabinet allows unobstructed airflow through the cooling path. An MOV network clamps incoming mains surges, and the power terminals accept conductors with a cross-sectional area of 35 mm².

Basic Cabinet Loss
100 W
Climatic category
3K3 according to EN 60721-3-3
Control Supply
24 VDC
Cooling Loss
360 W
Cooling Method
Air Cooled
Degree Of Protection
IP 20
Integrated power supply unit Output current
max. 2 A
Integrated power supply unit Output voltage
24 VDC
Line Frequency
50/60 Hz
Mains frequency
50 or 60 Hz
Mains Voltage
480 - 690 VAC
Max Ambient Temp
55 °C
Max Cooling Air Temp
45 °C
Max Output Current
800 A
Max Secondary Current
36 kA (PSG 3100)
Max. cooling losses
360 W
Min Clearance
100 mm
Nominal System Current
110 A
Overvoltage Protection
MOV
Product Type
Medium Frequency Inverter
Temperature range Operation
+10 -+55 ºC
Temperature range Storage / transport
-25 - +70 ºC
Timer Type
EtherNet
Weight
approx. 21 kg
Wire Range
35 mm²

Frequently Asked Questions about PSI63C0.772-L2:

Q: What is the compatible mains voltage range for the PSI63C0.772-L2 inverter?

A: The PSI63C0.772-L2 is designed to operate on mains voltages ranging from 480 to 690 VAC.

Q: What is the maximum output current for the PSI63C0.772-L2?

A: This inverter can handle a maximum output current of 800 A.

Q: How does the PSI63C0.772-L2 frequency inverter cool itself?

A: The PSI63C0.772-L2 uses an air cooled method to dissipate heat during operation.

Q: What minimum installation clearance is needed for the PSI63C0.772-L2?

A: A minimum clearance of 100 mm is required for the proper installation of the PSI63C0.772-L2.

Q: What is the IP protection rating for the PSI63C0.772-L2 inverter?

A: The degree of protection for the PSI63C0.772-L2 is rated at IP20.


Internal Product Review

  • ‘‘The PSI63C0.772-L2 is a medium frequency inverter that stands out for clean integration in demanding power conversion systems. Support for 480 - 690 VAC mains voltage and 800 A maximum output current gives the unit excellent operating flexibility and strong current delivery. Air-cooled operation and IP20 protection make the design well suited for controlled industrial cabinet applications.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo