The Bosch Rexroth Indramat PSI63C0.762-L2 is a medium frequency inverter from the PSI Frequency Inverters series. It supports mains voltages from 480 to 690 VAC with a maximum primary current of 800 Amps and maximum secondary current of 36 kA. The inverter is air cooled, has a protection rating of IP20, and weighs approximately 21 kilograms.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The PSI63C0.762-L2 is a medium-frequency inverter produced by Bosch Rexroth Indramat for the PSI Frequency Inverters series. In induction-heating stations and special machine tools, the unit converts three-phase mains power into a controlled high-frequency output that drives resonant transformer circuits and work coils. This role places the inverter between the plant supply and the load, where it meters energy, executes Ethernet-based timing commands, and exchanges 208 input bits and 160 output bits with a Profinet controller.

The power stage operates at an output carrier frequency of 1000 Hz while accepting utility voltages from 480 to 690 VAC at 50 or 60 Hz. Line current reaches 110 A under nominal loading, and cabinet heat dissipation at rated output is held to 200 W. The housing carries a protection rating of IP20, so it must be installed inside an electrical enclosure. Air-cooled channels remove thermal losses, while connection terminals accommodate conductors ranging from 35 mm² to 50 mm² to keep temperature rise within limits. Internal electronics draw 2 A from the integrated 24 V service rail, and climatic classification 3K3 indicates suitability for workshops that remain dry but experience moderate dust and vibration. Basic switch-cabinet losses are 100 W, and auxiliary blowers limit maximum cooling losses to 420 W. A secondary cooling-loss value of 360 W applies when the drive operates below peak power.

Primary-side surge events are managed by a bus that can momentarily accept 800 A. Downstream, the matching transformer can deliver up to 36 kA to the workpiece circuit. Control boards, sensors, and contactors are fed directly by the inverter’s auxiliary supply at 24 VDC. The overall mass is approximately 21 kg, which allows panel mounting without additional supports. Operation is permitted between +10 °C and +55 °C, while storage is possible at temperatures as low as -25 °C. If liquid intercooling is added, a water flow rate of 4 liters per minute creates a pressure drop of only 0.1 bar through the heat exchanger. Mains-frequency synchronization, an Ethernet timer, and Profinet I/O support closed-loop control within automated production cells.

Cabinet Losses At Max Power
200 W
Climatic category
3K3 according to EN 60721-3-3
Cooling Method
Air Cooled
Degree of protection
IP 20
Integrated power supply unit Output current
max. 2 A
Integrated power supply unit Output voltage
24 VDC
Internal Supply Current
2 A
Inverter Frequency
1000 Hz
Mains frequency
50 or 60 Hz
Mains Nominal Current
110 A
Mains Voltage
480 - 690 VAC
Max Cooling Losses
420 W
Max Primary Current
800 A
Max Secondary Current
36 kA
Max Terminal Cross-section
50 mm²
Max. cooling losses
360 W
Min Connection Cross-section
35 mm²
Min Water Flow
4 l/min
Product Type
Medium Frequency Inverter
Serial I/o (profinet)
208 In / 160 Out
Switch Cabinet Basic Losses
100 W
Temperature range Operation
+10 -+55 ºC
Temperature range Storage / transport
-25 - +70 ºC
Timer Type
EtherNet
Water Pressure Drop
0.1 bar at 4 l/min
Weight
approx. 21 kg

Frequently Asked Questions about PSI63C0.762-L2:

Q: What mains voltage does the PSI63C0.762-L2 frequency inverter support?

A: The PSI63C0.762-L2 inverter operates on a mains voltage range of 480 to 690 VAC, allowing compatibility with industrial high-voltage systems.

Q: How is the PSI63C0.762-L2 frequency inverter cooled?

A: This model uses air cooling as its cooling method, making it easy to maintain and operate without a liquid cooling system.

Q: What is the output current and voltage of the integrated power supply unit on the PSI63C0.762-L2?

A: The maximum output current from the integrated power supply unit is 2 A at 24 VDC, suitable for powering control circuits or external devices.

Q: What is the inverter frequency of the PSI63C0.762-L2?

A: The PSI63C0.762-L2 provides an inverter frequency of 1000 Hz, supporting a wide range of motor control requirements.

Q: What degree of protection does the PSI63C0.762-L2 inverter offer?

A: It is rated for IP20 degree of protection, meaning it is protected against touch but not against water entry.


Internal Product Review

  • ‘‘The PSI63C0.762-L2 is a medium frequency inverter rated for 480 - 690 VAC mains voltage and 1000 Hz inverter frequency. Air-cooled operation and IP20 protection make the design well suited for clean cabinet installations with dependable thermal behavior. A 24 VDC integrated power supply adds practical control support, and the 110 A mains nominal current highlights serious industrial capability.’’