The Bosch Rexroth Indramat PSI63C0.660-L2 is a medium frequency inverter from the PSI Frequency Inverters series. It operates with a mains voltage of 480 to 690 VAC and has a nominal system current of 110 amps. This air-cooled inverter has an IP20 degree of protection and weighs approximately 21 kilograms.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The PSI63C0.660-L2 is a medium-frequency inverter produced by Bosch Rexroth Indramat for the PSI Frequency Inverters series. In automated production cells, it converts high-voltage mains power into controlled medium-frequency power for induction heaters, hardening coils, or similar loads that require rapid energy transfer. The unit combines power electronics with an air-cooled heat sink to provide a compact source of programmable current for process sequences managed through DeviceNet timers or PLC interfaces.

The inverter can be connected directly to industrial power systems rated at 480–690 VAC, allowing use with European and North American high-voltage systems. Line compatibility is maintained at 50/60 Hz, so no external frequency adaptation is required. During dynamic peaks, the power stage delivers up to 800 A, while continuous output is limited to 110 A to keep semiconductor junction temperatures within safe limits. The enclosure has an IP20 protection rating, which helps prevent contact with live parts when the unit is mounted inside a control cabinet. Forced-air cooling removes heat from the semiconductors and busbars, and at least 100 mm of vertical clearance is required to maintain unrestricted airflow. MOV devices provide surge suppression, and current is measured with a resolution of 10 A. An integrated 24 VDC, 2 A supply provides power for external relays or sensors.

Operation is permitted from +10 to +55 °C, supporting stable performance in typical plant environments, while a storage range of -25 to +70 °C accommodates unconditioned warehouses. The unit weighs 21 kg and can be wall-mounted, while its copper bus links accept 35 mm² conductors and terminals up to 50 mm². Rated cooling losses of 360 W can be used when calculating panel ventilation requirements. A 1 kHz internal clock controls pulse patterns, while nine impulse slots and 256 program memories accommodate complex heating cycles. A 36 kA secondary current limit protects downstream work coils, and climatic category 3K3 under EN 60721-3-3 indicates suitability for dust-free indoor locations.

Climatic category
3K3 according to EN 60721-3-3
Clock Frequency
1 kHz
Cooling Method
Air Cooled
Current Resolution
10 A
Degree of protection
IP 20
Integrated power supply unit Output current
max. 2 A
Integrated power supply unit Output voltage
24 VDC
Mains frequency
50 or 60 Hz
Mains Voltage
480 - 690 VAC
Max Impulses
9
Max Output Current
800 A
Max Programs
256
Max Secondary Current
36 kA
Max. cooling losses
360 W
Min Vertical Clearance
100 mm
Nominal System Current
110 A
Overvoltage Protection
MOV
Product Type
Medium Frequency Inverter
Recommended Wire Size
35 mm²
Temperature range Operation
+10 -+55 ºC
Temperature range Storage / transport
-25 - +70 ºC
Terminal Capacity
50 mm² Max
Timer Type
Device Net
Weight
approx. 21 kg

Frequently Asked Questions about PSI63C0.660-L2:

Q: What is the acceptable mains voltage range for the PSI63C0.660-L2 frequency inverter?

A: The Bosch Rexroth PSI63C0.660-L2 operates with a mains voltage between 480 and 690 VAC.

Q: What is the maximum output current supported by the PSI63C0.660-L2?

A: This inverter has a maximum output current of 800 A, allowing for substantial load handling.

Q: How does the PSI63C0.660-L2 inverter protect against overvoltage conditions?

A: The PSI63C0.660-L2 provides overvoltage protection using an MOV (metal oxide varistor).

Q: What cooling method is used in the PSI63C0.660-L2 frequency inverter?

A: Air cooling is the designated method to maintain thermal management for this model.

Q: What are the output current and voltage specifications for the PSI63C0.660-L2's integrated power supply unit?

A: The integrated power supply unit delivers a maximum output of 2 A at 24 VDC.


Internal Product Review

  • ‘‘The PSI63C0.660-L2 is a capable medium frequency inverter built for controlled industrial power conversion. Strong electrical performance shows in the 480 to 690 VAC mains range and 800 A maximum output current, supporting demanding process loads with confidence. An integrated 24 VDC power supply with up to 2 A output adds practical control support, making the inverter a strong choice for high-demand installations.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo