Internal Product Review

The PSI63C0.181-L2 is a medium frequency inverter with a 480 to 690 VAC mains input and 50 or 60 Hz operation. Air-cooled construction and IP20 protection support dependable cabinet integration in controlled industrial environments. A 24 VDC integrated power supply rated to 2 A adds practical system support and rounds out a well-engineered inverter package.

Sell Part
Have a part to sell?
Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The Bosch Rexroth Indramat PSI63C0.181-L2 is a medium-frequency inverter in the PSI Frequency Inverters series. Designed for panel installation, it converts high-voltage utility power to the medium-frequency output required by induction heaters, test rigs, and other automated processes. In industrial automation, it delivers adjustable energy to the load while shielding upstream mains components from rapid load fluctuations. Its panel-mounted format allows the inverter to operate as part of a larger control system containing protection, switching, and process-control equipment.

The inverter accepts an input range of 480–690 VAC at 50/60 Hz, allowing the same device to operate with common North American or European industrial supplies without taps or transformers. An internal power module generates a stabilized control supply of 24 VDC and can provide up to 2 A. This onboard supply can energize compatible relays or field I/O without requiring a separate auxiliary transformer. The enclosure has an IP20 protection rating, which provides protection against accidental finger contact with live components but requires installation inside a suitable cabinet. Axial fans draw ambient air through the heat sink, and this air-cooled arrangement controls semiconductor temperatures without requiring a liquid cooling circuit.

Maximum cooling losses are rated at 360 W, which should be considered when calculating cabinet airflow or HVAC capacity. Continuous operation is permitted at ambient temperatures from +10 to +55 °C, while the storage range extends from -25 to +70 °C. The inverter has a mass of 21 kg, so firm mounting rails are required to support the unit and limit vibration. The unit complies with climatic class 3K3 under EN 60721-3-3, allowing operation in industrial atmospheres with moderate dust and noncondensing humidity. An integrated 24-volt timer circuit coordinates sequenced starts and stops for connected equipment. Adequate cabinet clearance must be maintained around the airflow path so that the axial fans can move cooling air across the heat sink without obstruction.

Climatic category
3K3 according to EN 60721-3-3
Cooling Method
Air Cooled
Cpu Type
TriCore
Degree of protection
IP 20
Front Width
239 mm
I/o Connection
24 V Discrete
Integrated power supply unit Output current
max. 2 A
Integrated power supply unit Output voltage
24 VDC
Mains frequency
50 or 60 Hz
Mains Nominal Current
110 A
Mains Voltage
480 - 690 VAC
Max Primary Current
800 A
Max Secondary Current
36 kA (PSG 3100)
Max. cooling losses
360 W
Min Cross-section
35 mm²
Number Of Programs
256
Overall Height
463 mm
Product Type
Medium Frequency Inverter
Temperature range Operation
+10 -+55 ºC
Temperature range Storage / transport
-25 - +70 ºC
Timer Type
24 V
Weight
approx. 21 kg

Frequently Asked Questions about PSI63C0.181-L2:

Q: What mains voltage does the PSI63C0.181-L2 frequency inverter support?

A: The PSI63C0.181-L2 operates on mains voltages between 480 and 690 VAC.

Q: How is the PSI63C0.181-L2 frequency inverter cooled?

A: This model is air cooled to manage operation and cooling losses.

Q: What are the output specifications of the integrated power supply on the PSI63C0.181-L2?

A: The PSI63C0.181-L2 inverter provides a 24 VDC output with a maximum current of 2 A from its integrated power supply unit.

Q: What is the degree of protection for the PSI63C0.181-L2 inverter?

A: The inverter is rated at IP20 for degree of protection, providing limited protection against solid objects but no protection against liquids.

Q: What is the allowable operating temperature range for the PSI63C0.181-L2?

A: The PSI63C0.181-L2 can be operated in temperatures from +10°C to +55°C.