PSI6300.256-L1 Bosch Rexroth Indramat
Wake Industrial LLC is not an authorized distributor of this product.
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat PSI6300.256-L1 is a medium frequency inverter from the PSI Frequency Inverters series. It operates with a mains voltage of 400 to 480 VAC and a nominal current of 110 Amps, offering air cooled operation with a maximum cooling loss of 360 Watts. The inverter features IP20 protection, integrated temperature monitoring, and a PROFIBUS I/O interface.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The PSI6300.256-L1 is a medium-frequency inverter manufactured by Bosch Rexroth Indramat for the PSI Frequency Inverters series. As a power-conversion unit, it delivers adjustable medium-frequency three-phase energy to induction heaters, welding generators, or similar loads in automated production lines. By processing a standard plant mains feed, the inverter lets motion, thermal, or forming processes synchronize with higher-level controllers while keeping the power section isolated inside a cabinet that meets industrial layout requirements.
It operates from a three-phase supply window of 400 – 480 VAC, and its insulation design tolerates phase-to-ground potentials up to 480 VAC to match common North American and European grids. The input stage draws a nominal current of 110 A, routed through frame terminals that accept conductors up to 50 mm², while the minimum permitted cable size is 35 mm². Cooling is handled by an air-cooled path, so a clearance of 100 mm must be left around the cabinet for unrestricted airflow. The steel door seals against a 3 mm gasket, and the enclosure carries an IP20 degree of protection suitable for installation inside electrical rooms. Both the I/O channel and the internal timer communicate on PROFIBUS, enabling parameter access and cycle coordination. Continuous heat dissipation is supervised by integrated temperature sensors that report to the same fieldbus.
Under light loading, the inverter introduces cabinet basic losses of 69 W. When the current reaches its calculated maximum, the internal losses rise to 170 W, and the ventilation system can remove up to 360 W of cooling losses. The primary bus can momentarily reach 800 A, while the matching PSG 3100 secondary circuit is rated to carry fault currents as high as 36 kA without mechanical damage. These electrical figures determine the protective equipment required around the unit and support the use of integrated temperature monitoring instead of relying only on external sensors.
Frequently Asked Questions about PSI6300.256-L1:
Q: What is the mains voltage range for the PSI6300.256-L1 frequency inverter?
A: This inverter operates on a mains voltage range of 400 to 480 VAC.
Q: Which communication interface does the PSI6300.256-L1 use?
A: The PSI6300.256-L1 supports PROFIBUS as its I/O interface.
Q: What cooling method is used in the PSI6300.256-L1 inverter?
A: This model is air cooled to manage operational heat.
Q: What is the degree of protection provided by the PSI6300.256-L1?
A: The degree of protection for this inverter is rated at IP20.
Q: What is the maximum primary current capacity of the PSI6300.256-L1 inverter?
A: The maximum primary current supported by the PSI6300.256-L1 is 800 A.