4.95 based on 203 reviews

🙶 Wake Ind. did a great job with very fast service getting us a motor driver to repair our critical robot sy... 🙷

PSI62C0.225-W1 Bosch Rexroth Indramat

Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat PSI62C0.225-W1 is a medium frequency inverter from the PSI Frequency Inverters series, weighing 56 kg and designed with IP20 protection degree. It uses water cooling with a minimum water flow of 4 liters per minute and achieves a maximum primary current of 1200 Amps at a mains voltage of 400 to 480 VAC. The inverter features a mains nominal current of 220 Amps, supports PROFIBUS timer type, and measures 653 by 288 by 280 mm.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The PSI62C0.225-W1 frequency inverter is produced by Bosch Rexroth Indramat as part of the PSI Frequency Inverters series. It is a medium-frequency inverter intended to power resistance-welding transformers and other loads that require controlled current in automated manufacturing cells. By converting three-phase plant power into a regulated waveform, the unit supplies the current needed for repeatable welding operations. This design supports precise control of the energy delivered to the workpiece during each programmed weld cycle.

The inverter accepts a line voltage of 400 to 480 VAC and draws a nominal line current of 220 A. Internally, it produces output pulses at 1000 Hz, allowing the connected transformer to provide high power from a compact assembly. Water serves as the cooling medium, and a pressure drop of 0.6 bar at 4 L/min across the heat exchanger keeps semiconductor junction temperatures within operating limits. Typical cabinet losses are 69 W, while losses can rise to 210 W at maximum utilization. The circuit can dissipate up to 700 W under the highest thermal load. The IP20 enclosure requires installation inside a suitable control cabinet, with at least 100 mm of ventilation clearance. The cooling circuit tolerates water pressure up to 10 bar, allowing it to connect to common industrial cooling systems without an additional pressure regulator.

On the primary side, the inverter can handle current bursts up to 1200 A. When paired with a PSG 3100 transformer, the secondary circuit can deliver welding current up to 54 kA to the workpiece. Conductors connecting the inverter to the line bus require a cross-sectional area of 95 mm² to control heating and voltage drop under load. The assembly weighs 56 kg and fits within an enclosure measuring 653 × 288 × 280 mm, supporting installation in industrial control cabinets. Serial communication is provided through PROFIBUS, and the integrated timer coordinates pulse sequences with upstream controllers and safety interlocks. This communication link allows the automation system to exchange operating commands, timing data, and inverter status information during production.

Cabinet Basic Losses
69 W
Cabinet Loss At Max %i
210 W
Cooling Method
Water Cooled
Cooling Pressure Drop
0.6 bar @ 4 l/min
Height X Width X Depth
653 x 288 x 280 mm
Mains Nominal Current
220 A
Mains Voltage
400 - 480 VAC
Max Cooling Losses
700 W
Max Primary Current
1200 A
Max Secondary Current
54 kA (PSG 3100)
Max Water Pressure
10 bar
Min Cooling Water Flow
4 l/min
Min Vent Clearance
100 mm
Product Type
Medium Frequency Inverter
Protection Degree
IP20
Required Cable Cross-section
95 mm²
Sequence Frequency
1000 Hz
Serial I/o
208 in / 144 out
Timer Type
PROFIBUS
Weight
56 kg

Frequently Asked Questions about PSI62C0.225-W1:

Q: What is the cooling method for the PSI62C0.225-W1 frequency inverter?

A: The PSI62C0.225-W1 frequency inverter uses water cooling as its cooling method.

Q: What is the maximum primary current the PSI62C0.225-W1 can handle?

A: This inverter has a maximum primary current rating of 1200 A.

Q: What cable cross-section is required for the PSI62C0.225-W1 frequency inverter?

A: The required cable cross-section for installation is 95 mm².

Q: What is the protection rating of the PSI62C0.225-W1 inverter?

A: The protection degree of the PSI62C0.225-W1 is rated at IP20.

Q: What is the minimum cooling water flow required for the PSI62C0.225-W1?

A: A minimum water flow of 4 liters per minute is necessary for proper cooling of this inverter.


Internal Product Review

  • ‘‘The PSI62C0.225-W1 is a highly capable medium frequency inverter with water-cooled thermal management and IP20 protection. From a technical standpoint, the 400 to 480 VAC input range and 1000 Hz sequence frequency support stable, responsive performance in demanding process equipment. Strong engineering and efficient operation make the inverter an excellent choice for high-duty industrial applications.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo