4.95 based on 202 reviews

🙶 Wake was very helpful in getting us a servo motor and drive for our tube mill line. This was the first tim... 🙷

PSI61C0.758-L1 Bosch Rexroth Indramat

Ask for Availability

Current response time:
6 Minutes 4 Seconds

Preparing your secure checkout page...

The Bosch Rexroth Indramat PSI61C0.758-L1 is a medium frequency inverter from the PSI Frequency Inverters series. It operates with an output current of 400 Amps, a mains voltage range of 400 to 480 Volts AC, and features IP20 protection. The inverter is air cooled, has a control supply of 24 Volts DC, and supports three input phases.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The PSI61C0.758-L1 belongs to the PSI Frequency Inverters series manufactured by Bosch Rexroth Indramat. It provides medium-frequency power conversion for industrial automation equipment by converting three-phase mains power into regulated current. The output can supply heating coils, transformers, or specialized drive systems that require controlled current profiles. Its cabinet-mounted design supports operation in systems where the inverter must coordinate power delivery with external controls and process equipment.

The inverter accepts a three-phase supply ranging from 400 to 480 VAC and can deliver up to 400 A to the connected load. Its gating electronics switch at 1 kHz, balancing waveform quality with semiconductor power losses during operation. The control electronics operate from a dedicated 24 V DC source, while separate 24 V I/O lines provide field-level signaling for connected devices. The IP20 housing protects against accidental finger contact with live components and is intended for installation inside an enclosed cabinet. An Ethernet-based timer supports synchronized triggering, and the internal program memory accommodates 256 steps for user-configured operating sequences. These timing and memory functions allow the inverter to coordinate current profiles without requiring continuous sequence control from an external PLC.

The unit tolerates ambient temperatures up to 55 °C, while the temperature of the cooling air should not exceed 45 °C. Forced airflow removes a continuous thermal load of 360 W from the power stage, helping internal components remain within their permissible operating range. On the secondary side of a PSG 3100 transformer, the inverter can withstand fault currents of 20 kA. The drive section supports a steady system current of 110 A during continuous operation. Power terminals accept cables with conductor sizes up to 50 mm², providing capacity for the inverter’s high-current connections. Control wiring connects through 35 mm² terminal blocks to accommodate the designated plant conductors and maintain secure electrical connections.

Ambient Temp Limit
55 °C
Climatic category
3K3 according to EN 60721-3-3
Clock Frequency
1 kHz
Control Supply
24 V DC
Cooling Air Temp
45 °C
Cooling Loss
360 W
Cooling Method
Air Cooled
Degree of protection
IP 20
I/o Voltage
24 V
Input Phases
3
Integrated power supply unit Output current
max. 2 A
Integrated power supply unit Output voltage
24 VDC
Mains frequency
50 or 60 Hz
Mains Voltage
400 - 480 VAC
Max. cooling losses
360 W
Output Current
400 A
Product Type
Medium Frequency Inverter
Program Capacity
256
Protection Rating
IP20
Secondary Current (psg 3100)
20 kA
System Current
110 A
Temperature range Operation
+10 -+55 ºC
Temperature range Storage / transport
-25 - +70 ºC
Terminal Capacity
50 mm²
Timer Type
EtherNet
Weight
approx. 20 kg
Wire Size
35 mm²

Frequently Asked Questions about PSI61C0.758-L1:

Q: What is the maximum ambient temperature for the PSI61C0.758-L1 inverter?

A: The PSI61C0.758-L1 frequency inverter can operate with an ambient temperature limit of up to 55 °C.

Q: What is the output current capability of the PSI61C0.758-L1?

A: This inverter features an output current rating of 400 A, suitable for large-scale industrial loads.

Q: What mains voltage and phase requirements are needed for operating the PSI61C0.758-L1 inverter?

A: The PSI61C0.758-L1 supports a mains voltage range from 400 to 480 VAC with three input phases.

Q: What cooling method does the PSI61C0.758-L1 use?

A: The cooling method used by this inverter is air cooled, requiring cooling air temperatures up to 45 °C.

Q: What level of protection does the PSI61C0.758-L1 inverter offer?

A: The PSI61C0.758-L1 provides protection rated at IP20, allowing installation in protected environments.


Internal Product Review

  • ‘‘The PSI61C0.758-L1 is a medium frequency inverter designed for 400 to 480 VAC mains input. Air-cooled construction and IP20 protection support dependable cabinet integration in demanding drive systems. A 400 A output current stands out as a strong advantage for high-load industrial applications.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo