PSI6100.327-L1 Bosch Rexroth Indramat
Wake Industrial LLC is not an authorized distributor of this product.
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat PSI6100.327-L1 is a medium frequency inverter from the PSI Frequency Inverters series. It operates with a mains voltage of 400 to 480 VAC, supports 3-phase input, and has a nominal system current of 110 Amps. This air cooled inverter offers IP20 protection, integrated temperature monitoring, and weighs approximately 20 kilograms.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The PSI6100.327-L1 is a medium-frequency inverter manufactured by Bosch Rexroth Indramat for the PSI Frequency Inverters series. It converts three-phase plant power into a controlled medium-frequency output for inductive loads such as heating coils, hardening stations, and resonant power supplies in automated equipment. A built-in control supply, temperature monitoring, and INTERBUS timing support enable the inverter to provide process power while exchanging operating data with a higher-level controller. The unit weighs approximately 20 kg and is intended for installation inside an appropriately protected electrical cabinet.
The input accepts 400–480 VAC at 50 or 60 Hz from a balanced three-phase power source. The nominal system current is 110 A, while the power stage can deliver up to 400 A rms to the output bus. A thyristor block provides a short-duration surge capability of 20 kA when used with the PSG 3100. The integrated power supply delivers 24 VDC at up to 2 A for external sensors, contactors, or fieldbus nodes. Metal-oxide varistors provide overvoltage protection for the DC link, and a 1 kHz clock controls the switching cycle. The wire terminals accommodate conductors with cross-sectional areas of up to 35 mm². An air-cooled heat sink manages operating temperatures from +10 °C to +55 °C, while the permitted storage and transport range extends from -25 °C to +70 °C.
Internal thermal dissipation starts at 69 W under light load and rises to 170 W at maximum power, so both operating conditions should be considered when planning cabinet ventilation. Total cooling losses can reach 360 W during continuous high-duty operation, and the monitored air channel shuts down the inverter if airflow becomes obstructed. The enclosure provides IP20 protection against finger contact with internal components but does not protect the unit against liquids. Adequate clearance around the heat sink is required to maintain unrestricted airflow and prevent excessive internal temperatures. The inverter is suitable for climate class 3K3 operating conditions under EN 60721-3-3 when installed within the stated temperature limits.
Frequently Asked Questions about PSI6100.327-L1:
Q: What is the required input power configuration and voltage range for the PSI6100.327-L1?
A: The PSI6100.327-L1 inverter is designed for 3-phase input power with a rated mains voltage range of 400 to 480 VAC.
Q: What is the maximum output current capacity of the PSI6100.327-L1 frequency inverter?
A: This model provides a maximum output current of 400 A during operation.
Q: What level of environmental protection does the PSI6100.327-L1 inverter offer?
A: The degree of protection for the PSI6100.327-L1 is IP 20, which allows limited ingress of dust and no protection against water.
Q: What are the output specifications of the integrated power supply unit in the PSI6100.327-L1 inverter?
A: The PSI6100.327-L1 features an integrated power supply unit that can output up to 2 A at 24 VDC.
Q: How is the PSI6100.327-L1 inverter cooled, and what is its maximum cooling loss?
A: The PSI6100.327-L1 uses air cooling and has a maximum cooling loss rating of 360 W.