NFE01.1-230-006 Bosch Rexroth Indramat
MPN: R911260059
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat NFE01.1-230-006 is part of the NFE Mains Filters series and operates with a nominal voltage of AC 230 V and a rated current of 6 Amps. This single-phase filter has a line frequency of 50 to 60 Hz and a protection rating of IP10. It can withstand an overload of 1.5 times the rated current for 1 minute per hour and functions within a temperature range of -25 to +85 degrees Celsius.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The NFE01.1-230-006 is a mains filter manufactured by Bosch Rexroth Indramat for the NFE Mains Filters series. In an industrial automation cabinet, this component is wired ahead of single-phase drive controllers or power supplies to attenuate conducted electromagnetic interference and keep unwanted noise from returning to the utility line. By placing the filter between the public grid and sensitive electronics, it helps the equipment and the surrounding network remain within electromagnetic compatibility limits.
The unit operates on line frequencies of 50–60 Hz and is designed for a nominal input of AC 230 V. Its internal inductors and capacitors are sized for a continuous load of 6 A, and the housing is arranged for single-phase wiring that is common in low-power automation panels. Voltage excursions are tolerated within +10% / -15%, allowing the filter to remain functional when supply levels drift during startup or under fluctuating plant demand. This operating range helps the filter continue working without overstressing its internal components.
The enclosure carries an ingress protection rating of IP10, so the terminals must be located inside a closed control cabinet. All internal parts are specified to function across a temperature span of -25 to +85 °C, which covers unheated storage and elevated ambient conditions near transformers or braking resistors. Short overloads up to 1.5 × rated current for 1 min/h can be withstood without permanent thermal damage, providing headroom for inrush or short production surges. Dielectric strength is verified by a line-to-line test of 2125 VDC for two seconds, while a separate 2800 VDC test to protective earth confirms insulation integrity. A minimum protective-earth conductor cross-section of 10 mm² is required to safely divert fault current.
Frequently Asked Questions about NFE01.1-230-006:
Q: What is the nominal voltage rating for the NFE01.1-230-006 mains filter?
A: The NFE01.1-230-006 operates on a nominal voltage of AC 230 V.
Q: How many phases does the NFE01.1-230-006 filter support?
A: This mains filter supports single-phase operation.
Q: What is the rated current of the NFE01.1-230-006?
A: It has a rated current capacity of 6 A for filtering applications.
Q: What is the minimum PE conductor size required for the NFE01.1-230-006?
A: The NFE01.1-230-006 is designed for use with 10 mm² minimum PE conductor size.
Q: What protection rating does the NFE01.1-230-006 possess?
A: It has a protection rating of IP10, offering basic protection against solid objects.