NFD01.1-440-050 Bosch Rexroth Indramat
Wake Industrial LLC is not an authorized distributor of this product.
MPN: R911263387
Ask for AvailabilityThe Bosch Rexroth Indramat NFD01.1-440-050 is a mains filter in the NFD Mains Filters series. It supports a nominal voltage of 440 V and a rated current of 50 Amps in a 3-phase configuration. The NFD01.1-440-050 offers IP10 protection and has an overload capacity of 1.5 times the nominal current for one minute per hour.
Internal Product Review
The NFD01.1-440-050 is a Bosch Rexroth Indramat mains filter built for 3-phase systems at 440 V. The 50 A rating and 1.5 × IN overload capacity make this unit a strong choice for stable performance in demanding power applications.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The NFD01.1-440-050 mains filter is produced by Bosch Rexroth Indramat within the NFD Mains Filters series. As a line-side component, it attenuates conducted interference between the supply network and Rexroth drive controllers in factory automation panels. By inserting impedance on each phase and routing leakage current to the protective earth, the device lowers electromagnetic emissions and improves the immunity of connected inverters and servo drives to network disturbances.
Designed for three-line installations, the filter handles a three-phase supply with a phase-to-phase reference point. Its nominal line voltage is 440 V, allowing direct installation on common industrial feeders without step-down transformers. The copper elements are sized for a continuous load of 50 A, so the series impedance remains linear under standard motor currents. A protective earth conductor cross-section of 10 mm² is required to return displacement current safely to ground and to meet touch-current limits for industrial equipment. With an enclosure rating of IP10, the unit is ventilated and intended for mounting inside a control cabinet where finger contact is prevented, while free airflow removes internally generated heat. The voltage reference for all ratings is phase-to-phase, which simplifies coordination with drive nameplate data.
Short transients above nominal are tolerated because the filter can carry 1.5 × IN for up to 1 minute per hour, enabling clearance of starting surges from large inverters without saturation of the cores. Dielectric strength is rated for 2125 VDC across the differential-mode path and 2800 VDC from line to protective earth. These margins limit leakage through the capacitive network and protect downstream equipment when lightning arresters or switching events raise network potential. Insertion loss is concentrated in the kilohertz range, which avoids unacceptable voltage drop at power frequency while still reducing conducted noise to support EMC compliance in drive systems.