Preparing your secure checkout page...

The Bosch Rexroth Indramat MLP300C-0060-FT-N0CN-NNL3 is part of the MLP Synchronous Linear Motors series and features a motor size of 300 with liquid cooling. It provides a continuous nominal force of 6720 Newtons and can reach a maximum force of 21500 Newtons. The motor operates with a rated current of 29.6 Amps and a winding resistance of 2.4 Ohms at 20°C.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The MLP300C-0060-FT-N0CN-NNL3 is a primary section from the MLP Synchronous Linear Motors series produced by Bosch Rexroth Indramat. As a liquid-cooled synchronous linear motor, it delivers direct thrust along a track without mechanical transmissions, making it suitable for high-speed pick-and-place axes, gantry stages, and machining centers that demand precise linear positioning. The design supports direct linear motion, so the drive system can move the carriage without gears, belts, or screw mechanisms in the force path.

This model produces a continuous nominal thrust of 6720 N while drawing a rated phase current of 29.6 A. Its force constant is 226.9 N/Amp, which indicates how much linear force the motor generates for each ampere supplied by the drive amplifier. Under rated conditions, the carriage can travel at a nominal velocity of 110 m/min, and the copper and iron losses removed by the cooling circuit amount to 3200 W. Heat is extracted through an internal channel fed by 4.6 L/min of coolant, and the inlet line may be pressurized up to 10 bar. The thermo-encapsulation method seals the windings, and power leads are routed through the front of the module to simplify cable routing inside the machine frame.

For short duty cycles, the motor can reach a peak thrust of 21500 N, and at that force the carriage attains a top speed of 60 m/min. A static attractive force of 30700 N must be considered when sizing air gaps and guide bearings. The laminated stator stack uses a 37.5 mm pole width that corresponds to winding code 0060, resulting in a winding inductance of 11.4 mH and a DC resistance of 2.4 Ω at 20 °C. Because no encoder is installed, external position feedback must be provided by the machine controller. Pressure drop across the cooling channel is 2.8 bar, and the voltage constant is 130.9 Vs/m for drive matching.

Attractive Force
30700 N
Continuous Nominal Force
6720 N
Cooling Type
Liquid Cooling
Electrical Connection
Wire Conducted through front
Encapsulation
Thermo-encapsulation Method
Force Constant
226.9 N/Amp
Heat Loss To Be Dissipated
3200 W
Max Velocity At Fmax
60 m/min
Maximum Current
143.1 A
Maximum Force
21500 N
Maximum Inlet Pressure
10.0 bar
Motor Encoder
No Encode Installed
Motor Size
300
Nominal Velocity
110 m/min
Pole Width
37.5 mm
Pressure Drop At Qmin
2.8 bar
Product Group
MLP Synchronous Linear Motors
Rated Current
29.6 A
Required Coolant Flow
4.6 l/min
Voltage Constant
130.9 Vs/m
Winding Code
0060
Winding Inductance
11.4 mH
Winding Resistance At 20 C
2.4 Ohm
  • mlp300c-0060-ft-n0cn-nnl3
  • MLP300C0060FTN0CNNNL3
  • MLP300C 0060 FT N0CN NNL3

Frequently Asked Questions about MLP300C-0060-FT-N0CN-NNL3:

Q: What is the continuous nominal force output of the MLP300C-0060-FT-N0CN-NNL3 linear motor?

A: The MLP300C-0060-FT-N0CN-NNL3 provides a continuous nominal force of 6720 N for sustained linear motion tasks.

Q: What cooling method is used in the MLP300C-0060-FT-N0CN-NNL3 linear motor?

A: This model uses liquid cooling, requiring an external coolant system for proper operation.

Q: What is the maximum force capability of the MLP300C-0060-FT-N0CN-NNL3 linear motor?

A: The maximum force generated by this linear motor is 21500 N during peak operational conditions.

Q: How is the electrical connection configured for the MLP300C-0060-FT-N0CN-NNL3?

A: The electrical connection is wire conducted through the front for this linear motor model.

Q: Does the MLP300C-0060-FT-N0CN-NNL3 linear motor include a motor encoder?

A: No encoder is installed on this motor, so position feedback must be arranged externally if required.


Internal Product Review

  • ‘‘The MLP300C-0060-FT-N0CN-NNL3 is an MLP synchronous linear motor with liquid cooling. Continuous nominal force of 6720 N and maximum force of 21500 N give the motor excellent thrust capability for demanding linear motion applications. Nominal velocity of 110 m/min supports high-throughput positioning, a strong fit for precision motion systems.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo