4.95 based on 202 reviews

🙶 Wake was very helpful in getting us a servo motor and drive for our tube mill line. This was the first tim... 🙷

MLP200B-0040-FT-N0CN-NNL3 Bosch Rexroth Indramat

MPN: R911347068

No Tariffs On US Orders
  • Rated 4.4 (47 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat MLP200B-0040-FT-N0CN-NNL3 is part of the MLP Synchronous Linear Motors series and features liquid cooling with a coolant flow of 3.2 liters per minute. It delivers a continuous nominal force of 3465 newtons and a maximum force of 10900 newtons, with a maximum current of 74.2 amps. The motor has a mass of 40 kilograms and uses a thermo-encapsulation method for encapsulation.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The MLP200B-0040-FT-N0CN-NNL3 is a synchronous linear motor primary section from Bosch Rexroth Indramat in the MLP Synchronous Linear Motors series. It delivers direct thrust for gantries and transfer stations. Physical features include motor size 200, length code B, and a thermo-encapsulated mass of 40.0 kg. Cooling is provided by a liquid circuit, and power leads exit the front face. This version has no integrated encoder, so position feedback must come from an external measuring device on the axis. Because force is produced directly along the travel path, the drive can support smooth linear motion on fast-travel axes.

The mover develops an attractive force of 15600 N, which is the magnetic preload that the guide system must withstand. Under continuous duty, it supplies 3465 N of thrust, and that level is limited by 2200 W of winding power loss removed by the coolant. A force constant of 251.4 N/A links thrust to phase current, so the rated phase current of 13.8 A produces nominal force without overheating. With a voltage constant of 145.1 Vs/m, the inverter must generate matching back EMF during motion. Electrical behavior is set by a winding resistance of 5.7 Ω and an inductivity of 29.7 mH, which correspond to winding code 0040. The pole width is 37.5 mm, and the internal leads use a conductor cross-section of 1.0 mm².

The assembly can generate 10900 N of peak thrust during short duty cycles, provided the inverter can momentarily supply 74.2 A per phase. Nominal velocity reaches 100 m/min under rated conditions, while speed at the maximum force point is limited to 40 m/min. The coolant circuit must move 3.2 l/min to stabilize temperature during these transients and keep the thermo-encapsulated winding package within its insulation class. Short bursts at this level are used for acceleration on transfer axes where force demand briefly rises above the continuous level. Stable coolant flow also helps reduce thermal buildup during repeated cycles.

Attractive Force
15600 N
Continuous Nominal Force
3465 N
Coolant Flow
3.2 l/min
Cooling Type
Liquid Cooling
Electrical Connection
Wire Conducted through front
Encapsulation
Thermo-encapsulation Method
Force Constant
251.4 N/A
Mass (thermal Encapsulation)
40.0 kg
Max Velocity At Fmax
40 m/min
Maximum Current
74.2 A
Maximum Force
10900 N
Motor Encoder
No Encode Installed
Motor Length
B
Motor Size
200
Nominal Velocity
100 m/min
Pole Width
37.5 mm
Power Loss
2200 W
Power Wire Cross-section
1.0 mm²
Product Group
MLP Synchronous Linear Motors
Rated Current
13.8 A
Voltage Constant
145.1 Vs/m
Winding Code
0040
Winding Inductivity
29.7 mH
Winding Resistance (20 °c)
5.7 Ohm
  • mlp200b-0040-ft-n0cn-nnl3
  • MLP200B0040FTN0CNNNL3
  • MLP200B 0040 FT N0CN NNL3

Frequently Asked Questions about MLP200B-0040-FT-N0CN-NNL3:

Q: What is the maximum force output of the MLP200B-0040-FT-N0CN-NNL3 motor?

A: The MLP200B-0040-FT-N0CN-NNL3 linear motor generates a maximum force of 10,900 N.

Q: What type of cooling system is used in the MLP200B-0040-FT-N0CN-NNL3 motor?

A: This linear motor uses liquid cooling and requires a coolant flow of 3.2 liters per minute.

Q: What is the continuous nominal force of the MLP200B-0040-FT-N0CN-NNL3?

A: The continuous nominal force for this model is rated at 3,465 N.

Q: What is the recommended power wire cross-section for the MLP200B-0040-FT-N0CN-NNL3?

A: Power wires for this motor have a cross-section of 1.0 mm².

Q: Does the MLP200B-0040-FT-N0CN-NNL3 come equipped with a motor encoder?

A: No encoder is installed by default on this linear motor model.