MLP140B-0090-FT-N0CN-N305 Bosch Rexroth Indramat
MPN: R911407951
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat MLP140B-0090-FT-N0CN-N305 is part of the MLP Synchronous Linear Motors series and has a motor size of 140 with a length B format. It features a continuous nominal force of 2415 N, a maximum force of 7650 N, and uses liquid cooling. The motor operates with an attractive force of 11000 N, a rated current of 14.0 A, and a power loss of 2512 W.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The MLP140B-0090-FT-N0CN-N305 is a primary section of a synchronous linear motor produced by Bosch Rexroth Indramat in the MLP Synchronous Linear Motors series. Intended for gantries, pick-and-place modules, and other positioning axes, the unit replaces rotary motion with direct linear thrust so mechanical transmissions are unnecessary. In an automation line, it generates controlled push-pull force along a magnetic track, allowing high acceleration, repeatable positioning, and low maintenance compared with ball-screw or belt drives.
At its continuous operating point, the mover delivers 2415 N while drawing a rated phase current of 14.0 A. That steady output is governed by a force constant of 172.80 N/A, so each ampere supplied through the three-phase winding directly scales the generated thrust. The coil set uses a 140 frame width with length code B and winding code 0090. Under rated excitation, it reaches a nominal carriage speed of 160 m/min, supported by a voltage constant of 99.7 Vs/m that corresponds to the back EMF seen by the drive. The winding resistance is 2.6 Ω and the inductance is 14.2 mH, which shape current-loop dynamics and inverter sizing.
When the application demands short bursts, the mover withstands a peak force of 7650 N and a corresponding peak current of 79.3 A, while the magnetic attraction to the secondary track reaches 11000 N. Heat produced during such peaks equals 2512 W of power loss, so the assembly uses liquid cooling. A flow of 3.6 L/min through the internal channel limits temperature rise with only 0.9 bar of pressure loss. Thermo-encapsulation secures the windings and contributes to a mover mass of 30.1 kg. Maximum traverse under full load is 90 m/min, and Hall-less operation is used because no encoder is installed. Power and sensor leads exit from the front of the housing to simplify cable routing.
Frequently Asked Questions about MLP140B-0090-FT-N0CN-N305:
Q: What is the continuous nominal force output of the MLP140B-0090-FT-N0CN-N305 linear motor?
A: The MLP140B-0090-FT-N0CN-N305 can deliver a continuous nominal force of 2415 N.
Q: What type of cooling does the MLP140B-0090-FT-N0CN-N305 use and what is the necessary coolant flow?
A: This motor features liquid cooling and requires a coolant flow of 3.6 liters per minute.
Q: What is the maximum velocity at full force for the MLP140B-0090-FT-N0CN-N305?
A: The MLP140B-0090-FT-N0CN-N305 achieves a maximum velocity of 90 meters per minute at maximum force.
Q: How is the electrical connection configured on the MLP140B-0090-FT-N0CN-N305?
A: The electrical connection is configured with a wire conducted through the front of the unit.
Q: Does the MLP140B-0090-FT-N0CN-N305 come with a motor encoder installed?
A: No encoder is installed on this linear motor model.