MLP100A-0120-FS-N0CN-NQNN Bosch Rexroth Indramat
MPN: R911341432
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat MLP100A-0120-FS-N0CN-NQNN is part of the MLP Synchronous Linear Motors series and utilizes liquid cooling with a recommended coolant flow of 2.0 liters per minute. This linear motor provides a continuous nominal force of 1180 Newtons, a maximum force of 3750 Newtons, and operates with a maximum current of 40.5 Amps. Its force constant is 160.40 N/A and the nominal velocity reaches up to 190 meters per minute.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The MLP100A-0120-FS-N0CN-NQNN is a primary section in the MLP Synchronous Linear Motors series produced by Bosch Rexroth Indramat. It is designed to generate linear thrust without mechanical conversion, forming the active part of a linear axis when paired with a passive secondary track. By energizing its windings with three-phase current, the unit travels along the track and positions tooling heads or gantry bridges in factory automation systems that demand high speed and repeatable force.
Tuned for continuous duty, the motor delivers a continuous nominal force of 1180 N. During acceleration, it reaches a maximum force of 3750 N, limited by magnetic saturation and current capacity. A rated current of 7.4 A sustains nominal thrust, while temporary peaks up to 40.5 A are tolerated. The force constant of 160.40 N/A indicates the proportional relation between current and output force. A winding inductivity of 43.8 mH affects current rise time and commutation behavior. A copper resistance of 7.9 Ω at 20 °C contributes to I²R losses and continuous heat generation. The primary exerts 5400 N of attractive pull toward the secondary, so rigid guides are required. With a voltage constant of 92.5 Vs/m, back EMF stays within inverter limits at the 190 m/min nominal velocity. Standard encapsulation protects the windings, and the power leads are routed through the front of the housing.
Heat is removed by liquid cooling, and the internal channels accept a coolant flow of 2.0 l/min with a max inlet pressure of 10.0 bar. This circuit dissipates the declared power loss of 1500 W, enabling a thermal time constant of 2.4 min and helping keep copper temperature stable when the axis runs at 120 m/min under full load. Motor size 100 with length code A provides a compact footprint for gantry carriages, and the absence of an encoder allows integration of an external feedback element suited to the control topology.
Frequently Asked Questions about MLP100A-0120-FS-N0CN-NQNN:
Q: What is the maximum force available from the MLP100A-0120-FS-N0CN-NQNN?
A: The MLP100A-0120-FS-N0CN-NQNN provides a maximum force output of 3750 N for demanding linear drive applications.
Q: What cooling method and flow rate are required for the MLP100A-0120-FS-N0CN-NQNN?
A: This model is equipped with liquid cooling and requires a coolant flow of 2.0 liters per minute for efficient operation.
Q: What is the continuous nominal force output of this linear motor?
A: The continuous nominal force delivered by the MLP100A-0120-FS-N0CN-NQNN is 1180 N for sustained performance.
Q: Does the MLP100A-0120-FS-N0CN-NQNN come with an installed motor encoder?
A: The MLP100A-0120-FS-N0CN-NQNN does not have a motor encoder installed for position feedback.
Q: What is the voltage constant of the MLP100A-0120-FS-N0CN-NQNN linear motor?
A: This linear motor is designed with a voltage constant of 92.5 Vs/m, affecting its dynamic performance and response.