KDV 1.3-100-220-300-W1-115-220 Bosch Rexroth Indramat
MPN: R911220672
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
Current response time:
3 Minutes
11 Seconds
The Bosch Rexroth Indramat KDV 1.3-100-220-300-W1-115-220 is a panel mount supply module from the KDV Supply Modules series. It supports a 220 V AC three-phase input voltage with a rated current of 100 A and supplies 300 V DC on the bus. The unit uses blower cooling and has an auxiliary power consumption of 500 VA, with a peak current of 300 A for 300 milliseconds.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The KDV 1.3-100-220-300-W1-115-220 is a supply module produced by Bosch Rexroth Indramat for the KDV Supply Modules series. It converts utility power into a stabilized DC link that feeds multiple servo drives, and it houses an internal bleeder stack to absorb regenerated energy during braking events. Deployed on the panel back-plane of an electrical cabinet, the unit forms the central power backbone for coordinated motion axes in industrial automation cells.
The module accepts a three-phase mains of 220 V AC, and its input path is rated for 100 A of continuous current under nominal conditions. Internally, it maintains a DC bus of 300 V DC, allowing drives to draw up to the module’s rated power limit of 30 kW. For short 300 ms transients, it can deliver a peak current of 300 A, enabling rapid motor acceleration without voltage sag. Non-drive loads such as logic circuits draw 500 VA of auxiliary power from an isolated secondary supply. While operating, the electronics dissipate 150 W into the cabinet, and the design permits a maximum of 2000 W to be carried away by external airflow, figures that guide enclosure ventilation sizing.
The regenerative path is dimensioned for 2 kW of continuous bleeder dissipation and a peak of 40 kW, so high-inertia stops do not overcharge the bus. Up to 60 kWs of feedback energy can be absorbed in a single braking cycle before thermal limits are reached. The assembly is blower cooled by an integral fan that consumes 15 VA at 115 V AC, keeping component temperatures within limits. Panel mounting simplifies service access, and the enclosure carries a protection rating of IP 10, giving basic shielding against accidental contact with live parts while relying on the cabinet for additional protection.
Frequently Asked Questions about KDV 1.3-100-220-300-W1-115-220:
Q: What input voltage is required for the KDV 1.3-100-220-300-W1-115-220 supply module?
A: The KDV 1.3-100-220-300-W1-115-220 is designed to accept a 220 V AC 3-phase input voltage.
Q: What is the DC bus voltage output of the KDV 1.3-100-220-300-W1-115-220?
A: This unit provides a DC bus voltage output of 300 V DC.
Q: What are the continuous and peak power ratings for the bleeder in this supply module?
A: The maximum continuous power handled by the bleeder is 2 kW, with a peak capability of 40 kW.
Q: How is the KDV 1.3-100-220-300-W1-115-220 supply module cooled?
A: Cooling is achieved using a blower that operates at 115 V AC and consumes 15 VA.
Q: What are the rated and peak current specifications for this supply module?
A: This model has a rated current of 100 A and can deliver a peak current of 300 A for 300 milliseconds.