IKG0041 Bosch Rexroth Indramat
Wake Industrial LLC is not an authorized distributor of this product.
MPN:
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat IKG0041 is part of the IKG Motor Power Cables series and features 4x2.5 mm² power conductors with total shielding. It has a PUR jacket in RAL 2003 orange and meets flame resistance standard EN 60332-1-2. The cable is suitable for drag chain use, offers a maximum fixed wire temperature of 90 C, and is oil resistant to EN 60811-2-1.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The IKG0041 is a flexible motor power cable produced by Bosch Rexroth Indramat for the IKG Motor Power Cables series. It is intended to link a drive controller to a servomotor in automated machinery, carrying both three-phase power and low-level control signals within a single routed harness. This arrangement supports compact cable routing while providing the electrical paths required for motor operation and auxiliary circuits. The cable is designed for constant bending in cable carriers used on pick-and-place axes, gantries, and other moving assemblies.
Four copper conductors with a cross-sectional area of 4 × 2.5 mm² deliver the main motor current, and their conductor resistance is limited to 7.98 Ω/km at 20 °C for predictable voltage drop over long runs. A braided and foil layer provides a total shield that attenuates electromagnetic interference and supports reliable operation with pulse-width-modulated drives. The insulation system limits signal-to-ground coupling to a discharge capacitance of 0.7 nF/m, helping control common-mode leakage. The PUR outer jacket passes the flame propagation test under EN 60332-1-2, while its orange RAL 2003 color increases visibility during installation in dense cable trays. The cable is also suitable for drag-chain use, allowing it to withstand repetitive movement in automated equipment without requiring a separate protective harness.
Two twisted pairs with a conductor layout of 2 × (2 × 1.0 mm²) accommodate encoder or brake circuits, keeping the low-current conductors separate from the power cores without requiring a second cable run. In a fixed installation, the cable can withstand conductor temperatures up to 90 °C. During continuous flexing, the allowable conductor temperature decreases to 80 °C to account for the additional mechanical stress associated with repeated movement. For machining centers exposed to soluble oils or hydraulic fluid, the PUR jacket resists swelling and cracking in accordance with EN 60811-2-1. Its resistance to lubricants helps preserve the jacket where moving cable carriers pass near machine tools, hydraulic equipment, or fluid-handling components.