HVR02.2-W025N/S204

MPN: R911327891

No Tariffs On US Orders
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The HVR02.2-W025N/S204 Power Supply Unit is manufactured by Bosch Rexroth Indramat.This unit operates with continuous DC bus power of 25 kW, peak DC bus power of 75 kW, mains voltage of 380 to 480 V, and maximum regenerated power of 80 kWs.

Quote Request Form:

Warranty
Wake Industrial Warranty
To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HVR02.2-W025N/S204 is a power supply unit which belongs to Bosch Rexroth’s HVR product line. It is installed inside DIAX04 control systems for providing DC power to drive control modules installed in the same chassis. The HVR02.2-W025N/S204 accepts three-phase AC input between 380 and 480 Volts AC. The input voltage is rectified by the supply unit and the DC voltage is provided to the compatible drive controllers. The HVR02.2-W025N/S204 is designed for regulated DC bus operation. Input transformers are not required under normal operating conditions. However input transformers may be required if the ambient thresholds recommended by Bosch for the HVR02.2-W025N/S204 supply are exceeded. The rated continuous power output of the HVR02.2-W025N/S204 is 25 kilowatts. The supply output can go up to 75 kilowatts for a duration of 0.3 seconds.

Power loss for the HVR02.2-W025N/S204 when it is operating with continuous output power is 750 Watts. Power losses per kilowatt for the DC bus when the supply is operating at continuous output power are 24 Watts per kilowatt. The supply comes with a blower for facilitating convection cooling. Bosch has also specified minimum spacing requirements when the HVR02.2-W025N/S204 is installed inside a cabinet. These minimum spacing requirements are: 90 millimeters in front of the supply, 80 millimeters on top of the supply and 100 millimeters below the supply. IP10 rated enclosure of the supply measures 498 x 175 x 262 millimeters. A two-place seven-segment display is provided on the front panel of the HVR02.2-W025N/S204 to signal operating status and faults. Control voltages of +24 Volts, +5 Volts and ±15 Volts are required for fault diagnosis. Errors on the supply can be reset by generating reset command, by switching off the control voltage or by pressing the RESET button. This unit can be shipped globally with a one-year warranty period from Wake Industrial.

Continuous Power
25 kW
Mains Voltage
380 to 480V
Maximum Regenerated Energy
80 kWs
Peak Power
75 kW
  • HVR022W025NS204
  • HVR02 2 W025N S204
  • hvr02.2-w025n/s204
  • HVR2.2-W025N/S204

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo